630502_4
DS
1400 Indoor Outdoor Installation
Sill Detail - installation dependant upon house cladding choice.
selected cladding
on cavity
floor structure
base extension panel
with 5mm air gap
to the window joinery
air seal
alum. awning window
with timber reveal
provided spacer
bracket
DS1400 Gas Fire
glass viewing area
xx
150
5
convected hot air void
- pathway shown
external framed wall
wall underlay with
flexible flashing tape
overlaid to sill
WANZ support bar
where required
convected fresh air void
- pathway shown
‘xx’ - This value will be impacted by cladding choice and cavity requirements - minimum value is 150mm.
Recommended building materials include:
• Sika Book FR - Air Seal
• Thermokraft building wrap - Wall Underlay
• Alutape Xtreme - Flexible Flashing Tape
• Construction adhesive: Loctite MP5000, Liquid Nails, No More Nails, Nailbond SB Original or Nailbond Premium