8.
Using
a
multimeter,
verify
that
the
voltage
at
the
ac
outlet
is
correct.
Attaching
the
front
or
back
ac
electrical
outlet
You
might
need
to
attach
an
ac
outlet.
Use
the
procedure
in
this
section
to
perform
this
task.
Attention:
The
front
and
back
ac
outlet-mounting
plates
mount
through
the
same
mounting
holes
in
that
secure
the
stabilizer
brackets
to
the
rack
chassis.
Therefore,
if
the
rack
must
be
bolted
to
the
floor,
the
stabilizer
brackets
must
be
removed.
Install
the
ac
outlet-mounting
plates
only
after
the
rack
has
been
bolted
to
the
floor
and
the
stabilizer
brackets
have
been
removed.
The
following
items
are
installed
at
the
customer’s
site:
v
The
ac
outlet-mounting
plates
for
installing
customer-supplied
ac
electrical
outlets
on
the
front
or
back
of
the
rack.
The
ac
outlet-mounting
place
provides
the
mounting
location
for
an
ac
electrical
outlet.
v
The
brass
ground
lug
for
an
electrostatic
discharge
(ESD)
connection.
Note:
The
customer
is
responsible
for
providing
both
the
outlets
and
the
power
cables
that
attach
to
the
power
source.
The
customer
is
also
responsible
for
connecting
the
ac
outlet
correctly.
These
items
are
not
field-replaceable
units
(FRUs).
Installing
the
ac
outlet-mounting
plates
with
ac
outlets:
You
might
need
to
install
ac
mounting
plates.
Use
the
procedure
in
this
section
to
perform
this
task.
If
you
do
not
want
ac
outlets
installed
on
the
rack,
go
to
“Installing
the
ac
outlet-mounting
plate
without
ac
outlets”
on
page
30.
If
you
want
ac
outlets
installed
on
the
front
or
back
ac
outlet-mounting
plate,
do
the
following:
1.
Determine
the
number
of
ac
outlets
that
you
are
installing.
2.
Confirm
with
your
contractor
that
the
number
and
location
of
ac
outlets
to
be
installed
are
correct.
3.
Remove
the
blank
filler
plates
from
the
ac
outlet-mounting
plates
for
the
number
of
ac
outlets
being
installed.
4.
Install
the
ac
outlets
on
the
ac
outlet-mounting
plate.
5.
Install
the
ground
lug
in
the
ac
outlet-mounting
plate
using
only
one
nut,
as
shown
in
the
following
illustration.
6.
Securely
tighten
the
one
nut
on
the
ground
lug.
7.
Locate
the
″
Y
″
-shaped
ground
cable
supplied
with
the
mounting
plate.
Note:
The
remaining
steps
can
be
used
to
install
ac
outlets
on
the
front
or
the
back
of
the
rack.
8.
Place
the
star
washer
onto
the
ground
lug
of
the
front
ac
outlet-mounting
plate.
9.
Place
the
lug
on
the
long
end
of
the
ground
cable
onto
the
ground
lug.
10.
Place
a
ground
lug
nut
onto
the
ground
lug
and
securely
tighten
it.
11.
Position
the
front
ac
outlet-mounting
plate
onto
the
rack
frame
with
the
ground
lug
fully
inserted
through
the
mounting
holes
in
the
rack.
12.
Route
the
cable
under
the
rack.
13.
Place
the
star
washer
onto
the
ground
lug
of
the
back
ac
outlet-mounting
plate.
14.
Place
the
lug
on
the
short
end
of
the
ground
cable
onto
the
ground
lug.
15.
Place
a
ground
lug
nut
onto
the
ground
lug
and
securely
tighten
it.
28
Installation
Guide
for
the
03E/4A,
07M/15,
and
08M/25
Summary of Contents for PL160R
Page 1: ...PL160T R PL260T T and PL460T R Installation Guide ESCALA REFERENCE 86 A1 55EW 01...
Page 2: ......
Page 10: ...viii Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 12: ...2 Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 14: ...4 Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 54: ...44 Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 96: ...86 Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 98: ...88 Installation Guide for the 03E 4A 07M 15 and 08M 25...
Page 105: ......
Page 106: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 55EW 01...