GAS TAP MAINTENANCE
IMPORTANT!
The installation must be carried out by a suitably qualified
and licensed gas fitter and in accordance with the current
standards.
WARNING!
Before carrying out any maintenance operations, always
isolate the cooktop from the electricity and gas supplies.
If a gas tap becomes stiff to operate, then you should
proceed as follows:
► Remove the control knobs, pan supports, burners, hob
fixing screws and clamps.
► Remove the hob from the worktop and remove any
underside protective covers.
► Disconnect the fixings holding the tap to the fascia
panel and separate the assembly. Then clean the cone
and seating, with a cloth dampened with solvent.
► Lightly smear the cone with high temperature grease,
reassemble into position and rotate a few times.
► Remove the cone again and remove any excess grease,
making sure that the gas ducts are not obstructed with
grease.
► Carefully reassemble the components and perform a
gas soundness test.
If it becomes necessary to replace a gas tap, then you should
proceed as follows:
► Remove the control knobs, pan supports, burners, hob
fixing screws and clamps.
► Remove the hob from the worktop and remove any
underside protective covers.
► Disconnect the fixings holding the tap to the fascia
panel and separate the assembly.
► Disconnect the gas pipe from the gas tap, and then
disassemble them from the gas rail by removing the
fixing screws.
► When fitting a new tap, ensure that a new gasket is
used.
► Reconnect the gas tap, perform a gas soundness test,
and then reassemble the hob.
ELECTRICAL CONNECTION
IMPORTANT!
The installation must be carried out by a suitably qualified
and licensed person and in accordance with the latest
edition of the AS/NZS 3000 Wiring Regulations and in
compliance with the instructions outlined within this user
manual.
WARNING!
240 Volts. Disconnect power before servicing the cooktop.
Before connecting the appliance, make sure that the supply
voltage marked on the rating plate corresponds with your
mains supply voltage.
► Cable type: H05 RRF 3 core x 0.75 mm³ (Type RR-F
<HAR> marked).
► The mains supply cable is supplied with this product.
If the mains supply cable is damaged, then it must be
replaced by an appropriate replacement, which can be
obtained from Residentia Group, or an authorised service
agent.
The mains supply cable should be replaced in accordance
with the following instructions and by suitably qualified
and
licen
ced person:
► Switch the appliance off at your mains supply.
► Open the box of the supply board.
► Unscrew the clamp fixing the cable.
► Replace the cable with one of the same length and in
accordance with the specification given above.
► The “green-yellow” earth wire must be connected to
the terminal marked . It must be about 10 mm longer
than the live and neutral wires.
► The “blue” neutral wire must be connected to the
terminal marked with letter (N) - the live wire must be
connec