VENTILATION REQUIREMENTS
► The room containing the hob should have an air supply
in accordance with AS/NZS5601.1 Gas Installations.
► The room must have opening windows or equivalent;
some rooms may also require a permanent vent.
► It will require an air vent of 300 mm² per MJ/h (eff ective
area) to outside, or 600 mm2 per MJ/h (ef ective area) to
adjacent room. (See total gas consumption in MJ/h on
the appliance rating plate).
► If there are any other fuel burning appliances in
the same room the standardAS/NZS5601.1 Gas
Installations: should be consulted to determine air vent
requirements.
► Ensure that the room containing the hob is well
ventilated, keep natural ventilation holes or install
a mechanical ventilation device (mechanical cooker
hood).
► Prolonged intensive use of the appliance may call
for additional ventilation, either by the opening of a
window, or by increasing the level of the mechanical
ventilation device (where present).
► This hob is not fi tted with a device for discharging the
products of combustion. Ensure that the ventilation
rules and regulations are followed.
► The walls behind and near the hob should be resistant
to heat, steam and condensation.
GAS CONNECTION
Install in accordance with relevant gas standards and/or
codes of practice applicable.
Connect the elbow fi tting to the appliance gas manifold
connection, and check that seals between the elbow and
manifold connection are in place and in good condition.
► For NG or LPG you need to install the regulator
( picture
right
) supplied with the appliance. There regulator has
a
test point to enable an anthourised licenced plumber /gasfitter to
check for gas leaks after the cooktops installation.
Screw LPG setting
Screw NG setting
Gas pressure test point
DUAL GAS REGULATOR AND VALVE
INTRODUCTION
Inlet pressure setting: of natural gas 6 in.wc / liquefied gas
11 in.wc of.
THE PEROFRMANCE PARAMETERS OF THE FOLLOWING TABLE
This product is a low-pressure pipeline regulator valve
for built-in gas appliances. Natural gas and
LPG
conversion function, need to be set
manually.
operating temperature: -20 - 60
℃ ℃
Installing the gas regulator
When installing the gas regulator, ensure that its valve
outlet thread matches the thread of the gas connector.
Use an appropriate sealant around the threads.
Ensure that the gas regulator valve installation location is
perpendicular. After installation, open the gas source switch
and check the valve body connections with soap and water for leaks.