MyLab
- G E T T I N G S T A R T E D
7 - 7
GETTI
NG STARTED
The procedure can be stopped at any time by pressing the
CANCEL
button. In
this case the CD/DVD is unusable.
Performing the Exam
By pressing the different mode keys, the specific mode is activated in real time. If
the same key is pressed again, the system automatically returns to the previous
presentation.
Line Cursor
Press
LINE UPDATE
to display the scanning line. During the scan this key freezes
the trace and re-activates the 2D reference; the
PLEX
button activates or freezes
the 2D reference, maintaining the trace in real time.
The control panel keys and the commands displayed on the touchscreen make it
possible to optimize presentation quality. Different menus correspond to each
format.
When more modes are active, the navigation tabs (
B-M O D E
,
M -M O D E
...) allow the
operator to scroll among the specific mode menu. If the displayed menu has
several levels, press the button
A DV >>/ BA S IC< <
to scroll through all functions.
2D and CFM
To save images and sequences, press
IMAGE
and
CLIP
. These keys respectively
save still frames and clips in real time. Images are also saved in Freeze. Clips are
acquired in Prospective Mode: the
CLIP
key starts the acquisition. The number of
captured loops depends on the set value (
CLIPS DUR
toggle).
Single images are saved with full definition or compressed, whereas sequences are
compressed with a minimum loss of information.
Traces
In the case of traces (M-Mode, Q-Mode, Compass M-Mode and Doppler) the key
IMAGE
saves the image displayed on the screen. When the trace is displayed in cine
mode (
P LA Y
key), the
ACQUIRE
key allows to save the corresponding clip.
AO
Compression of both images and clips to be saved on external media can be set:
refer to the “Clinical and System Settings” section for further information.
Note
When burning data, do not use any Double Layer DVD disk nor
disks with applied stickers.
Summary of Contents for 350009500
Page 1: ...Rev 02 April 2016 MyLabDelta GETTING STARTED 350009500 ...
Page 10: ...MyLab G E T T I N G S T A R T E D 6 ...
Page 17: ...MyLab G E T T I N G S T A R T E D 1 7 GETTING STARTED ...
Page 18: ...MyLab G E T T I N G S T A R T E D 1 8 ...
Page 19: ...MyLab G E T T I N G S T A R T E D 1 9 GETTING STARTED ...
Page 26: ...MyLab G E T T I N G S T A R T E D 1 16 ...
Page 34: ...MyLab G E T T I N G S T A R T E D 2 8 ...
Page 40: ...MyLab G E T T I N G S T A R T E D 3 6 ...
Page 68: ...MyLab G E T T I N G S T A R T E D 5 12 ...
Page 76: ...MyLab G E T T I N G S T A R T E D 6 8 ...
Page 88: ...MyLab G E T T I N G S T A R T E D 7 12 ...