LM11
CH21:
Calibration of the current value set with the remote wireless current setting
receiver.
-
Set the S2 setting location switch to WIRELESS position
-
Remove the ZW1 jumper located on the LM11 board and insert it into the ZW2.
-
Using the R24 potentiometer set the value of 400A (for ORIGOArc 410c), 650A
(for ORIGOArc 650c) and 800A (for ORIGOArc 810c).
-
Insert the ZW2 jumper located on the LM11 board back to ZW1 and set the S2 setting
switch to LOCAL position.