Voltage meter calibration
-
Set the V/A switch located on the cap board to the V position (voltage measurement)
-
Connect the reference voltmeter to output terminals of the source
-
Using the R12 potentiometer located on the LM11 board set the voltage indication for no-
load voltage of the source according to the indication of the reference device