© ESAB AB 2012
- 11 -
bb01de
4.5
Mains power supply
WARNING
The welding power source is connected for 400 V at delivery. For other mains
voltage, reconnect on the terminal block, according to the connection instructions
on page 24.
Tighten the screws
A
using a torque of 10 Nm. Ensure that the plastic protector
B
is
still loose.
Make sure that the welding power source is connected to the
correct mains voltage and that it is protected by the correct
fuse rating. A protective earth connection must be made in
accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes
Aristo 1000
50/60 Hz at DC welding
Mains voltage
380V
400V
415V
440V
460V
500V
550V
575V
Phase current
I
1eff
86A
82 A
79A
74A
71A
66A
59A
57A
Fuse
anti-surge
100A
100A
80A
80A
80A
80A
63A
63A
Note!
The fuse sizes as shown above are in accordance with Swedish regulations. Use the welding
power source in accordance with the relevant national regulations.