installation
30
input terminal BoarD
230/460 Vac moDels
230 VAC CONFIGURATION
200/230/460 Vac models
- As shipped from the factory, this model of EPP-202 is configured for the highest
connectable voltage. If using other input voltages, the links on the terminal board (TB) inside the unit must be
repositioned for the appropriate input voltage. See illustrations below for input voltage configurations. To gain
access, remove the top panel or right side panel.
input terminal BoarD
230/460 Vac moDels
460 VAC CONFIGURATION
input Voltage configuration and changeover
Jumper Wire
Jumper Wire
Unit is also configurable for 200/400 VAC input service, but the main transformer secondary connections must
be re-located on all 3 transformer coils, and jumper wires on the TB2 must be re-positioned. A removable service
panel is located above the transformer connections to improve access.
Summary of Contents for 0558011310
Page 2: ...EPP 202 Plasma Power Source 2...
Page 4: ...EPP 202 Plasma Power Source 4...
Page 7: ...SAFETY...
Page 8: ...SAFETY 8...
Page 21: ...DESCRIPTION...
Page 22: ...description 22...
Page 25: ...INSTALLATION...
Page 26: ...installation 26...
Page 39: ...installation 39 J1 RAS Interface Cable CAN Cables...
Page 40: ...installation 40...
Page 41: ...OPERATION...
Page 42: ...OPERATION 42...
Page 50: ...OPERATION 50...
Page 51: ...MAINTENANCE...
Page 52: ...Maintenance 52...
Page 57: ...TROUBLESHOOTING...
Page 58: ...58 TROUBLESHOOTING 58...
Page 65: ...REPLACEMENT PARTS...
Page 66: ...Replacement Parts 66...
Page 68: ...Replacement Parts 68...
Page 69: ...revision history 1 Originally released 01 2015 2 Revision 10 2015 added RotorFlow Sensor...