![Erreka RINO-I Quick Installation And Programming Manual Download Page 7](http://html1.mh-extra.com/html/erreka/rino-i/rino-i_quick-installation-and-programming-manual_2424325007.webp)
7
P274Z
LB/ LR
A.T. (ST1)
COM
SG.C (FT1)
COM
A.P. (ST2)
SG.A (FT2)
AUX
(12Vdc)
FT
RIS1000EIC: 230V/50-60Hz
RIS1000EICM: 125V/50-60Hz
N
L
T
G1
G2
COM
60W max
(1.250/2.300W max)
COM
G2
G1
3~
M
1~
M
J7
Pos 1
Pos 2
J7
DL26
F1
F2
F3
F4
General connections
(photocell without
testing)
(photocell with testing)
(1250/2300W max)
60W max
red
white
green
brown
black
gray
Do not use acapacitor
for the motor.
F1
Main Fuse (3A)
F2
Primary Fuse (0.5A)
F3
Secondary Fuse (1A)
F4
Peripheral Fuse (0.315A)
DL26
DC bus LED
M274C
A
B
ESC
ENTER
P4
P3
D1 and D2:
CL
8º
(static)
Gate closed
CL
88
(flashing)
Gate closing
OP
88
(static)
Gate open
OP
88
(flashing)
Gate opening
PC
88
(flashing)
Pedestrian door closing
PO
88
(static)
Pedestrian door open
PO
88
(flashing)
Pedestrian door opening
XX
88
(countdown)
Gate on standby
PA
88
(static)
Pause (operation not complete)
StOP
Operator unlocked
HEAt
Excessive heating inverter module
COç
Communication failure with inverter module
D3 and D4 (during operation):
88º
Â
8
FT2 activated
888º
Â
FT1 activated
88º
@
8
Flashing light
888º
@
green traffic light activated
88º
+
8
Internal FCC activated
888º
+
Internal FCA activated
88º
?
8
2nd radio channel (or RSD)
888º
?
1st radio channel signal
88º
-
8
External FCC activated
888º
-
External FCA activated
88º
¨
8
ST2 activated
888º
¨
ST1 activated
88º
â
8
LG activated
888º
â
red traffic light activated
D3 and D4 (in case of failure):
88
C4
Opening safety device activated
88
C5
Closing safety device activated
88
C9
Safety strip enabled
88
E1
Encoder motor shutdown
88
F1
Force limit exceeded
Display indications
The display can be placed in position “B” for
easier programming. Once finished, return to
"A” position before positioning the frame.
P3
: communication with inverter module
P4
: encoder active