10
A
0
Flashing light
0
1
x
No pre-warning, static output
0
2
With pre-warning, static output
1
Garage light time
0
...
5ÿ
0
...
9
03
59
= 59 secs;
2ÿ5
= 2 min. 50 secs, etc
2
Gate speed
T h e o p e n / c l o s e r u n m u s t b e
r e p r o g r a m m e d w h e n e v e r t h i s
parameter is changed
0
1
...
9
03
01
: minimum speed (40Hz);
02
: 45Hz,
03
: 50Hz,
04
: 55Hz, ...
09
: maximum speed (80Hz)
3
Slowdown speed
T h e o p e n / c l o s e r u n m u s t b e
r e p r o g r a m m e d w h e n e v e r t h i s
parameter is changed
0
1
...
9
03
01
: minimum speed (21Hz);
02
: 22Hz,
03
: 23Hz,
04
: 24Hz, ...
09
: maximum speed (29Hz)
6
Maximum entrapment current (each
value equivalent to 0.5A)
The digit D3 can be used to adjust
current to normal speed
The digit D4 can be used to adjust
current to slow speed
0
...
9
0
...
9
00
00
: disabled;
01
: disabled at normal speed and 0.5A at
slow speed;
10
: 0.5A at normal speed and disabled at
slow speed; ...;
65
: 3A at normal speed and 2.5A at slow
speed;...;
99
: 4.5A at normal and slow speed
7
Closing photocell crossed during
standby (in automatic mode only)
0
0
No effect
0
1
Immediate closing after crossing
0
2
x
Restart standby time
8
Effect of pushbuttons (ST1, ST2) during
stand-by time (in automatic mode only)
0
0
No effect
0
1
Cause immediate close
0
2
x
Restart stand-by time
9
Opening mode
0
1
Collective opening
0
2
x
Semi-automatic alternative shutdown
0
3
Automatic alternative shutdown (only in
automatic mode,
F2
K
00
b
Using the EPS1 card connector
For parameters
Ab02
and
Ab03
, use
the EPS1 card and bridge the network
input cable connectors instead of
disconnecting them from the network.
0
0
x
use for standard traffic light
0
1
use for brakes
0
2
NC contact with gate open (L1-COM) and
gate closed (L2-COM)
0
3
impulse 1 second Open (L1-COM) when
starting opening and Close (L2-COM) when
starting closing. Allows another board to be
activated
E
Special functions
0
0
x
no special function
0
2
industrial
(1.5s delay in shutdown and reversing)
ç
0
Programming lock key
Be sure to remember any key used, for
future access to programming
X
X
0000
The preset option is
0000
(no key). If any
figure is changed, this is considered a key.
Select the required key (starting with D1)
using UP and DOWN. Press ESC to cancel or
ENTER to confirm and move to D2, and so
on.
1
Operations carried out (total counter)
X
X
Indicates the hundreds of cycles completed
(for example,
68
indicates 6,800 cycles
completed)
2
Operations carried out (partial counter,
restarts with ST1 and ST2)
X
X
Indicates the hundreds of cycles completed
(for example,
68
indicates 6,800 cycles
completed)