MAINTENANCE
Before carrying out any maintenance operation, disconnect the device from the power supply.
1
Frequently check the installation in order to discover
any imbalance or sign of deterioration or wear. Do
not use the operator if any repair or adjustment is
necessary.
2
Clean and lubricate the joints and tracks of the gate,
so as not to increase the strain of the operator.
3
Check that the key devices, strips and photocells, as
well as their installation, have not suffered any
damage from the weather or external agents.
4
Check unlocking can be carried out easily.
5
Check the operations in the display (see “Operations
counter” below).
2
OPERATIONS COUNTER
1
Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
ç
.
D3 and D4 show the number of operations
carried out (hundreds of operations).
3
Press ESC to return.
D1
D2
Parameter
D3
D4
Default option Options or values
ç
1
Operations carried out
X
X
Indicates the hu ndred s of cycles
completed (for example,
68
indicates
6,800 cycles completed
)