EROSTEK ET312 User Manual Download Page 7

7

12 VDC Input

 - This is where you connect the supplied AC Power Adapter to charge the 

battery. 

Use only the adapter supplied with your unit or one approved by ErosTek.

 Early 

ET312s came with a 12VDC 

unregulated

 adapter that had a fixed input voltage — 120 

VAC in the USA and 240 VAC in EU and other countries — and a variable output voltage 

which depended on the load applied. The newest ET312s ship with a worldwide universal 

AC adapter that provides a 

regulated

 output of 15VDC and comes with different AC plugs 

to connect to most power outlets.  In either case, an output having a center positive (+) 

polarity with 500mA rating is required for connection to the ET312. 

Connecting a higher 

output voltage or one with the wrong polarity will most likely damage the charging circuit 

inside the ET312.

 

Output A & B

 - The output jacks are labeled “A-Out-B” and each operates independently. 

Most erotic accessories will either plug right into these jacks or can be used with the 

supplied banana plug cables. If you want to use TENS style pads, or certain other 

electrodes, we stock a range of cables, adapters and accessories on our online shop. You 

can also purchase 3.5mm (1/8”) 2 conductor (mono) plugs and cables at your ErosTek 

dealer or local electronics store. 

Always make connections with the ET312 turned OFF.

Audio Input

 - Using the supplied stereo cable, you can connect most any audio device 

with a headphone jack to this input. Some common audio sources include portable music 

players, smartphones, the sound output from a computer or “sound and light” relaxation 

devices. You may want to use a widely-available “Y” cable allowing you to connect both the 

ET312 and your headphones to the audio device. 

Disconnect audio devices when you are 

not using them.

 Audio devices should only be used in the audio modes.

Microphone Input

 - Connect the supplied microphone to this input for creative audio 

stimulation. Other microphones may also be used. See 

Advanced Topics

 section A5 for 

more information.

Link Connector

 - This is a proprietary digital interface that serves multiple purposes. 

First, it allows the ET312 to be connected to a personal computer running ErosLink™ 

software (see section A6). The cable and software are available separately. Second, it 

allows two ET312 units to be connected together in a master slave configuration. The 

slave unit will “mirror” what the master unit is doing providing four channels of stimulation 

controlled from one unit. Linking two units requires an inexpensive optional 

Link Cable

 

available from our online shop, or you can fabricate your own — see Section A2.

IMPORTANT!

 — 

Make certain you never connect an audio device, computer, or 

microphone, to the A or B Output jacks!

 While this will not harm the ET312, it can easily 

damage the external equipment. Unfortunately, the erotic e-stim industry standardized 

on a common audio connector for their accessories. This makes it easy to plug things 

into the wrong jacks and subject external equipment to the e-stim signals. 

Always make 

connections with the power turned OFF.

Connections

Summary of Contents for ET312

Page 1: ...ET312 User Guide...

Page 2: ...inability to use the Product even if the Manufacturer was aware of the possibility of such damages Indemnity Purchaser hereby releases and agrees to indemnify and hold harmless the Manufacturer from a...

Page 3: ...ge of 18 Current passed through the heart neck or head can be fatal Keep away from children The ET312 is intended for use only by healthy consenting adults familiar with safe electrostimulation and pr...

Page 4: ...iencing hands free orgasms Still others use it for erotic BDSM play where it creates high intensity sensations without causing the lingering discomfort and possible harm you get with other techniques...

Page 5: ...his Guide Like many things in life electrostimulation is not without risks It must be performed properly and there are certain people who should not use ANY electrostimulation devices including the ET...

Page 6: ...ements Symmetrical bipolar output waveforms for balanced and flows Standard 3 5mm output connectors Independent and electrically isolated outputs 6 CONNECTIONS The ET312 has six connection jacks along...

Page 7: ...ome common audio sources include portable music players smartphones the sound output from a computer or sound and light relaxation devices You may want to use a widely available Y cable allowing you t...

Page 8: ...nel Diagram on the next page for control locations and descriptions Power Switch The power switch is located just to the left of the connection jacks Make your connections and turn the level controls...

Page 9: ...rrent mode and adjustments Menu Key optional advanced settings Up Key selects next mode or setting MultiAdjust adjusts stimulation sensations Level A and B adjusts intensity of outputs A and B Down Ke...

Page 10: ...Indicators A red LED for each channel is located under the LCD display These provide an approximate indication of what the output is doing This is especially useful if you re using the ET312 on someo...

Page 11: ...may want to turn down the levels slightly before changing modes Waves This mode constantly adjusts several parameters differently for each channel This results in creative interplay between the channe...

Page 12: ...ther stereo music source Popular dance and other music with a defined beat tends to work best Classical or other music with soft passages may interrupt the stimulation Audio 3 This mode is like Audio...

Page 13: ...tiny pinch of baking soda or contact lens saline solution mixed in Some conductive rubber accessories may limit the intensity due to their design and become less conductive with repeated use Electrode...

Page 14: ...12 with a low battery will greatly reduce the battery life If the unit is not being used charge the battery every 6 months 13 CARING FOR YOUR ET 312 The ET312 like most electronic devices should be tr...

Page 15: ...To cancel a ramp and return the unit to normal just change the mode The Ramp Up function does not work in the Random1 mode This function offers some very interesting options It can be used to graduall...

Page 16: ...used on the slave unit to adjust the intensity of the third and fourth channels The link works in most but not all modes If you desire four channels of audio stimulation use a Y cable or two micropho...

Page 17: ...ning to the end of the ramp This is more of an in crease than many people are comfortable with Setting it to 100 effectively disables the Ramp function RampTime Adjust This allows you to adjust the ti...

Page 18: ...TriPhase can be used two ways The standard method uses three electrodes with one common connection between the two channels As shown in the diagram on Page 19 the striped wire of each channel is conne...

Page 19: ...es are available on the Internet and can be played back using iTunes or other music player software They can also be encoded as MP3 files and played back using a computer or a portable music player So...

Page 20: ...as those used to repair eye glasses Failure Messages If a failure message is displayed the error codes below may indicate the likely problem 04 Link Failure The slave ET312 did not respond correctly...

Page 21: ...loss damage or injury to Purchaser others and property arising out of the use misuse or inability to use the product Recovery of any kind against the Manufacture shall not exceed the purchase price of...

Page 22: ...d to ErosTek products Treat the ET312 like a sharp knife or power tool It must be used properly or serious injury may result CE Compliance Connected lead wires must be less than 3 meters 118 long Cust...

Page 23: ...23 Notes...

Page 24: ......