A6: ErosLink and Troubleshooting

A6: EROSLINK COMPUTER INTERFACE

With the optional 

ErosLink

 software and cable, you can add up to six new routines to your 

ET312 at one time, share routines with others, and even design your own.

The 

ErosLink

 cable can also be used to upgrade the actual internal software that runs the 

ET312. Check 

erostek.com

 for more information on 

ErosLink

 and upgrade options.

TROUBLESHOOTING

Self Test

 - The ET312 runs a complete check every time you power it on and monitors 

various conditions while operating. If any problems are found, the ET312 is designed to 

shut off the outputs and either reset itself or display an error message.

Low Battery Message

 - Normally this means you need to connect the AC adapter and 

charge the battery. If you keep getting this message, leave the unit off to charge for awhile. 

It can also mean the wrong AC adapter is being used or it’s not connected properly.

LCD Adjustment

 - The LCD normally does not require any adjustment. If the ET312 is 

operated in unusually hot or cold areas, the LCD adjustment can be used to optimize the 

contrast. Use a small flat blade screwdriver such as those used to repair eye glasses.

Failure Messages

 - If a failure message is displayed, the error codes below may 

indicate the likely problem:

• 

04 Link Failure

 - The slave ET312 did not respond correctly 

• 

15 User Mode Failure

 - Invalid data was found in a User mode 

• 

20 Calibration Error

 – Allow ET312 to reach room temperature before powering ON.

• 

21 Power Failure

 - The wrong AC adapter may cause this code

If any other code number is displayed, it may indicate an internal problem with your ET312. 

If you continue to receive a failure message, note the failure number and contact ErosTek 

LEDs Blink On Power Up

 - This could happen if a software upgrade did not complete 

properly or if the 

MENU

 and 

UP

 keys are held down during power up. Try turning the power 

off and back on again. If the LEDs still blink, there is a problem with the internal software 

and it needs to be reloaded. See 

blog.erostek.com

 for information on installing new 

software in your ET312.

Other Problems

 - If your unit fails to operate properly, hold down the 

UP

 and 

DOWN

 

keys before turning on the power and keep them held down until the self test completes. 

This will reset the unit to the factory settings. Having an audio source connected when 

using non-audio modes can cause some unusual variations. Make sure the problem isn’t 

caused by the cables or your accessories. 

Summary of Contents for ET312

Page 1: ...ET312 User Guide...

Page 2: ...inability to use the Product even if the Manufacturer was aware of the possibility of such damages Indemnity Purchaser hereby releases and agrees to indemnify and hold harmless the Manufacturer from a...

Page 3: ...ge of 18 Current passed through the heart neck or head can be fatal Keep away from children The ET312 is intended for use only by healthy consenting adults familiar with safe electrostimulation and pr...

Page 4: ...iencing hands free orgasms Still others use it for erotic BDSM play where it creates high intensity sensations without causing the lingering discomfort and possible harm you get with other techniques...

Page 5: ...his Guide Like many things in life electrostimulation is not without risks It must be performed properly and there are certain people who should not use ANY electrostimulation devices including the ET...

Page 6: ...ements Symmetrical bipolar output waveforms for balanced and flows Standard 3 5mm output connectors Independent and electrically isolated outputs 6 CONNECTIONS The ET312 has six connection jacks along...

Page 7: ...ome common audio sources include portable music players smartphones the sound output from a computer or sound and light relaxation devices You may want to use a widely available Y cable allowing you t...

Page 8: ...nel Diagram on the next page for control locations and descriptions Power Switch The power switch is located just to the left of the connection jacks Make your connections and turn the level controls...

Page 9: ...rrent mode and adjustments Menu Key optional advanced settings Up Key selects next mode or setting MultiAdjust adjusts stimulation sensations Level A and B adjusts intensity of outputs A and B Down Ke...

Page 10: ...Indicators A red LED for each channel is located under the LCD display These provide an approximate indication of what the output is doing This is especially useful if you re using the ET312 on someo...

Page 11: ...may want to turn down the levels slightly before changing modes Waves This mode constantly adjusts several parameters differently for each channel This results in creative interplay between the channe...

Page 12: ...ther stereo music source Popular dance and other music with a defined beat tends to work best Classical or other music with soft passages may interrupt the stimulation Audio 3 This mode is like Audio...

Page 13: ...tiny pinch of baking soda or contact lens saline solution mixed in Some conductive rubber accessories may limit the intensity due to their design and become less conductive with repeated use Electrode...

Page 14: ...12 with a low battery will greatly reduce the battery life If the unit is not being used charge the battery every 6 months 13 CARING FOR YOUR ET 312 The ET312 like most electronic devices should be tr...

Page 15: ...To cancel a ramp and return the unit to normal just change the mode The Ramp Up function does not work in the Random1 mode This function offers some very interesting options It can be used to graduall...

Page 16: ...used on the slave unit to adjust the intensity of the third and fourth channels The link works in most but not all modes If you desire four channels of audio stimulation use a Y cable or two micropho...

Page 17: ...ning to the end of the ramp This is more of an in crease than many people are comfortable with Setting it to 100 effectively disables the Ramp function RampTime Adjust This allows you to adjust the ti...

Page 18: ...TriPhase can be used two ways The standard method uses three electrodes with one common connection between the two channels As shown in the diagram on Page 19 the striped wire of each channel is conne...

Page 19: ...es are available on the Internet and can be played back using iTunes or other music player software They can also be encoded as MP3 files and played back using a computer or a portable music player So...

Page 20: ...as those used to repair eye glasses Failure Messages If a failure message is displayed the error codes below may indicate the likely problem 04 Link Failure The slave ET312 did not respond correctly...

Page 21: ...loss damage or injury to Purchaser others and property arising out of the use misuse or inability to use the product Recovery of any kind against the Manufacture shall not exceed the purchase price of...

Page 22: ...d to ErosTek products Treat the ET312 like a sharp knife or power tool It must be used properly or serious injury may result CE Compliance Connected lead wires must be less than 3 meters 118 long Cust...

Page 23: ...23 Notes...

Page 24: ......

Reviews: