EROSTEK ET312 User Manual Download Page 15

15

Advanced Topics – Introduction and Menus

A1: ADVANCED INTRODUCTION

Consider the ET312 similar to an advanced camera. Most users let their cameras set the 

exposure, focus automatically, decide when to use the flash, etc. In a similar way, the 

ET312 normally automates several adjustments. Some users, however, may want more 

control. 

This section is intended for advanced users and is optional reading.

A2: MENUS

Main Menu

 - Pressing the 

MENU

 key enters the main menu. The 

UP

 and the 

DOWN

 

keys now display various menu options and the 

OK

 key selects a displayed menu item. To 

return to normal operation without making any changes, simply press the 

MENU

 key again.

Start Ramp Up?

 - Pressing 

OK

 will immediately reduce the intensity of both channels 

and slowly ramp it back up again. The amount of reduction and the ramp time are 

adjustable in the Advanced Adjustment Menu. The ramp time can be adjusted from less 

than one minute to more than an hour. The ramp level is displayed on the LCD. 

To cancel a ramp and return the unit to normal, just change the mode. 

The Ramp Up function does 

not work

 in the 

Random1

 mode.

This function offers some very interesting options. It can be used to gradually increase 

the output over time to adjust for the normal desensitization that occurs during prolonged 

e-stim. Used this way, the perceived output level will remain approximately constant. 

It can also be used to deliberately increase the intensity over time which some people find 

highly erotic. It can challenge the user to complete the ramp cycle much like a weightlifter 

is challenged to complete a certain workout routine. In a BDSM scene, letting the person 

connected to the ET312 see the slowly increasing display can be especially arousing. 

Set Split Mode?

 - Pressing 

OK

 allows you to select which two modes are used when 

Split is selected. So, for example, you might choose 

Audio 1

 for Channel A and 

Waves

 for 

Channel B or one of 80 other combinations. Simply select the mode for A, press 

OK

, then 

select the mode for B and press 

OK

Not all modes are available to 

Split

 as some require both channels to function correctly and 

certain combinations may not work as expected.

Summary of Contents for ET312

Page 1: ...ET312 User Guide...

Page 2: ...inability to use the Product even if the Manufacturer was aware of the possibility of such damages Indemnity Purchaser hereby releases and agrees to indemnify and hold harmless the Manufacturer from a...

Page 3: ...ge of 18 Current passed through the heart neck or head can be fatal Keep away from children The ET312 is intended for use only by healthy consenting adults familiar with safe electrostimulation and pr...

Page 4: ...iencing hands free orgasms Still others use it for erotic BDSM play where it creates high intensity sensations without causing the lingering discomfort and possible harm you get with other techniques...

Page 5: ...his Guide Like many things in life electrostimulation is not without risks It must be performed properly and there are certain people who should not use ANY electrostimulation devices including the ET...

Page 6: ...ements Symmetrical bipolar output waveforms for balanced and flows Standard 3 5mm output connectors Independent and electrically isolated outputs 6 CONNECTIONS The ET312 has six connection jacks along...

Page 7: ...ome common audio sources include portable music players smartphones the sound output from a computer or sound and light relaxation devices You may want to use a widely available Y cable allowing you t...

Page 8: ...nel Diagram on the next page for control locations and descriptions Power Switch The power switch is located just to the left of the connection jacks Make your connections and turn the level controls...

Page 9: ...rrent mode and adjustments Menu Key optional advanced settings Up Key selects next mode or setting MultiAdjust adjusts stimulation sensations Level A and B adjusts intensity of outputs A and B Down Ke...

Page 10: ...Indicators A red LED for each channel is located under the LCD display These provide an approximate indication of what the output is doing This is especially useful if you re using the ET312 on someo...

Page 11: ...may want to turn down the levels slightly before changing modes Waves This mode constantly adjusts several parameters differently for each channel This results in creative interplay between the channe...

Page 12: ...ther stereo music source Popular dance and other music with a defined beat tends to work best Classical or other music with soft passages may interrupt the stimulation Audio 3 This mode is like Audio...

Page 13: ...tiny pinch of baking soda or contact lens saline solution mixed in Some conductive rubber accessories may limit the intensity due to their design and become less conductive with repeated use Electrode...

Page 14: ...12 with a low battery will greatly reduce the battery life If the unit is not being used charge the battery every 6 months 13 CARING FOR YOUR ET 312 The ET312 like most electronic devices should be tr...

Page 15: ...To cancel a ramp and return the unit to normal just change the mode The Ramp Up function does not work in the Random1 mode This function offers some very interesting options It can be used to graduall...

Page 16: ...used on the slave unit to adjust the intensity of the third and fourth channels The link works in most but not all modes If you desire four channels of audio stimulation use a Y cable or two micropho...

Page 17: ...ning to the end of the ramp This is more of an in crease than many people are comfortable with Setting it to 100 effectively disables the Ramp function RampTime Adjust This allows you to adjust the ti...

Page 18: ...TriPhase can be used two ways The standard method uses three electrodes with one common connection between the two channels As shown in the diagram on Page 19 the striped wire of each channel is conne...

Page 19: ...es are available on the Internet and can be played back using iTunes or other music player software They can also be encoded as MP3 files and played back using a computer or a portable music player So...

Page 20: ...as those used to repair eye glasses Failure Messages If a failure message is displayed the error codes below may indicate the likely problem 04 Link Failure The slave ET312 did not respond correctly...

Page 21: ...loss damage or injury to Purchaser others and property arising out of the use misuse or inability to use the product Recovery of any kind against the Manufacture shall not exceed the purchase price of...

Page 22: ...d to ErosTek products Treat the ET312 like a sharp knife or power tool It must be used properly or serious injury may result CE Compliance Connected lead wires must be less than 3 meters 118 long Cust...

Page 23: ...23 Notes...

Page 24: ......

Reviews: