Ergoswiss 901.20024 Operating Instruction Download Page 7

 

 

 

 

 

 

 

Operating Instruction 

Spindle lifting system SL/SM compact

 

 

 

Document no.: B-00061 

Edition 2018 02

 

operating instruction EN 

Copyright by Ergoswiss AG

 

7/23 

 

2.2

 

Basic safety instructions 

The safety instructions must be paid attention to. If the system is operated improperly, it can cause danger 

to people and objects!  
 
It is essential to read this operating instruction thoroughly before commissioning the system. This operating 

instruction has to be stored in the immediate vicinity of the system. 
 

 

In no case the control box may be opened! There is the risk of an electrical shock. 

 

 

Modifications or changes to the control box, the manual control switch, the motor and any connection 
cables are forbidden! 
 

 

The control box must only be operated with mains voltage indicated on the name plate!  

 

 

The supplied power cable must be used. It is forbidden to operate the control box with a damaged 
power cable! 

 

 

Electrical cables must not be exposed to crushing hazard or to bending and tensile loads. 

 

 

Before connecting/disconnecting the manual control switch the power cable has to be disconnected 
from the mains! 

 

 

The control box must not be operated in a potentially explosive atmosphere! 

 

 

The control box must be protected from moisture, dripping water as well as spray water! 

 

 

The control box is not suitable for continuous use. The operation/hold ratio must not exceed 2/18.  
 

 

If there is a failure (for example, if the control drives on its own, or if a push button is stuck) the power 
cable is to be separated from the mains immediately! The power cable must be freely accessible at any 

time. 
 

 

While using the height adjustment of the work surface there is a danger of squeezing. It is important to 

make sure that no objects or people are within the danger zone and no one is reaching into the danger 
zone. 
 

 

This device is not intended to be used by people (including children under 8) with restricted physical, 

sensory or mental abilities or with a lack of experience and/or knowledge, unless they are supervised by 
a person responsible for safety or they have received instructions by this very person on how to operate 
the device. 
 

 

Children under 8 should be supervised to ensure that they do not play with the device. 

 

 

If the power cable of the drive is damaged it must be replaced by the manufacturer, the manufacturer's 
customer service or by a similar qualified person. 
 

 

Only use a dry or a damp cloth to clean the control box! Before cleaning, the power cable has to be 

separated from the mains! 

 

 

Summary of Contents for 901.20024

Page 1: ...trol switch up down or memory Example of a table frame with two lifting columns Qrossbar Table feet Errors and technical changes reserved Ergoswiss AG does not assume any liability for operating error...

Page 2: ...Number of lifting columns 1 2 3 2440 Spindle pitch in mm 3 mm 4 mm 2440 Stroke length in cm 30 cm 40 cm EU Power cable EU CH IT UK US 01 01 Manual control switch up down 02 Memory 01 02 compact Spind...

Page 3: ...switch Memory Touch 11 4 Initial operation 12 4 1 Plug detection 12 5 Operation 13 5 1 Drive up down 13 5 2 Duty cycle monitoring 13 5 3 Saving a memory position Only with manual control switch type M...

Page 4: ...rrent height of the work surface is contin uously shown on the display cm or inch Up to four different memory positions can be stored and ap proached individually 1 2 Specified normal operation The li...

Page 5: ...350 Nm Mby stat 900 Nm Max dyn Bending moment Mbx dyn 150 Nm Mby dyn 450 Nm 1 4 3 Motor SL SM 24 V Nominal voltage 24 V Nominal torque 3 Nm Idle speed 150 min 1 Nominal power 92 W Nominal current 4 A...

Page 6: ...diate threatening danger Non compliance with this information can result in death or serious personal injuries disabil ity WARNING Indicates a possible dangerous situation Non compliance with this inf...

Page 7: ...a potentially explosive atmosphere The control box must be protected from moisture dripping water as well as spray water The control box is not suitable for continuous use The operation hold ratio mu...

Page 8: ...ox and connecting the cables Mounting of the control box underneath a table top ATTENTION During mounting of the control box the power cable needs to be disconnected from the mains 1 Place the control...

Page 9: ...therwise the danger of damage or destruction of the device can arise 1 Connect the motor cables to the control box Automatic plug detection 2 Connect the manual control switch to the control box 3 Con...

Page 10: ...The front edge of the manual control switch should not stick out of the edge of the table 2 Fasten the manual control switch using the mounting screws Be careful not to drill through the table top 3 2...

Page 11: ...m 2 Fasten the mounting plate using the mounting screws Be careful not to drill through the table top 3 Slide the manual control switch onto the mounting plate 3 2 4 Manual control switch Memory Touch...

Page 12: ...ea and no one is reaching into the danger zone ATTENTION The lowest block position must always be reachable The lifting element is not allowed to hit a stop before it reached its lowest block position...

Page 13: ...operated again 5 3 Saving a memory position Only with manual control switch type Memory With this function it is possible to memorise a certain position height and approach it at a later time by push...

Page 14: ...ntainer is placed un derneath the desktop A container stop position can be defined in the lower half of the movement area a shelf stop position in the upper half If a container stop position is set th...

Page 15: ...manual control switch type Memory 1 Press the buttons 1 2 and simultaneously until S 5 or S 7 is displayed 2 Press the button until S 0 appears on the display 3 Press the button S Save Control box cli...

Page 16: ...t can be connected and synchronised The length of the SYNC 2 cable is 550 mm The SYNC cable cannot be extended If necessary the motor cables can be extended NOTE Always do reset before disconnecting D...

Page 17: ...box is connected to the mains If the SYNC cables are connected afterwards they will not be recognised by the control box and only one drive will move which can lead to jamming of the entire system NOT...

Page 18: ...rd or upward movement the motor will stop instantly and turn back for one motor turn 4 mm The safety strip 124 00105 consists of 7 1 Technical Data Functional properties of the contact tube Contact an...

Page 19: ...safety strip both can also be connected with the split cable Gluing the contact tube in the squeeze zone Connecting the safety strip 1 Clean and degrease the contact face 2 Pull off a liner of acryli...

Page 20: ...and cleaning The spindle lifting system is maintenance free for up 10 000 cycles while observing the specified normal op eration Therefore servicing is not necessary ATTENTION The control box and the...

Page 21: ...roup 1 49 Excess current motor group 2 60 Collision protection 62 Excess current control 36 Plug detection at motor socket M1 Plug in the motor cable correctly at the respective socket Reset the syste...

Page 22: ...able Motor defective Contact the customer service Control box defective Contact the customer service Manual control switch defective Replace the manual control switch Bad connector contact Plug in all...