EN
FLOW
Model
d
D
D1
E
A
C
F*
FLOW 4
100
103
143
52
33
11
8
FLOW 5
125
128
164
58
34
12
10
FLOW 150
150
153
200
69
42
13
10
FLOW 6
160
163
200
66
42
13
-
*- This size is present only in fans with “back flow valve” option
S3
Legend of circuit breaker S1
on the scheme
Сircuit breaker S1
External switch S2
Built-in switch S3 (pull chain
switch)
Legend of external switch
S2 on the scheme
Legend of built-in switch S3
on the scheme
INSTALLATION AND SET UP PROCEDURES
ERA fans are mounted both with airvents and independently.
ERA fans are intended for wall mounting. Models of ERA fans with a ”BB” option are
applied to wall and ceiling mounting.
Mounting of ERA fans is carried out as with ventilating air ducts and independently
on a plain vertical or horizontal surface, for models with a “BB” option on a plain
vertical surface of sufficient rigidness for installation of a product by means of screws.
Tolerance range of a mounting surface in vertical and horizontal directions is ±0,5 mm.
SCHEMATIC DIAGRAMS OF ERA FAN`S CONNECTION
Scheme 1
of fan connectuion (base model)
X- terminal block, 2 pairs
* Fans should only be connected to the AC network
rated voltage 12 V (Marked on the fan case and
packaging)
Scheme 2
of fan connection, equipped with - 02 option (pull-chain
switch).
X2- terminal block, 3 pairs
Scheme 3 (for E / NEO /QUADRO
models)
of fan connection, equipped with - 02 option(pull-chain
switch)
X- terminal block, 2 pairs
WIRING DIAGRAM CONNECTION OF ERA FANS TO THE
NETWORK
Connection of fan to the network shown in pic. 1-14
COMFORT / FAVORITE (pic. 1)
• remove the decorative front panel
• hold the power wire through the cable hole
1 in the case
• strip the insulation on 5-7 mm from the
wire end
• insert wires into terminal box X and press
them by tap screw
• fix the wires by means of cable clamp 2
• combine clamps of the decorative panel with
grooves in the case
• fix the panel with screw