Rev. A
Disassembly, Assembly, and Adjustment 5-25
TM-U200 Series (Type A/AM) Technical Manual
C o n fid e n tia l
Main Assembly 10
Sensor assembly
1. Insert the sensor portion of the sensor assembly into the base frame assembly; then attach
the board by pushing it in.
2. Press the board down to attach it completely.
3. Attach the paper detector switch to the base frame assembly.
✓
Make sure the sensor board is not damaged.
4. Hook the sensor assembly lead wires to the base frame assembly as shown in the illustration.
5. Position the paper detection switch sub assembly lead wires as shown in the illustrations,
and make sure that the lead wires are as close as possible to the base frame surface.
Sensor assembly
Base frame assembly
Paper detector switch
Paper detection switch sub assembly lead wires