Rev. A
Disassembly, Assembly, and Adjustment 5-29
TM-U200 Series (Type A/AM) Technical Manual
C o n fid e n tia l
Main Assembly 13
Print head unit
1. Attach the print head FPC to the print head unit.
2. Place the print head FPC under the hooks on the carriage sub assembly, and then secure the
print head unit to the carriage sub assembly with the screw.
3. Place the print head FPC under the hooks on the carriage sub assembly, and then secure the
print head unit to the carriage sub assembly with the screw.
✓
Make sure there is space between the slanting edge of the print head FPC and slanting side
of the carriage sub assembly, and between the FPC edge and portion A. If there is no space,
the print head FPC may not be inserted into the print head unit firmly. Remove the print
head unit and insert the print head FPC again.
CPP-tite (M3x10)
[0.49 to 0.69 N • m
(5 to 7 kgf • cm)]
Print head unit
Print head FPC
O-10 application points
Carriage sub assembly
Hooks
A
There must be space