5-54
Disassembly, Assembly, and Adjustment
Rev. A
C o n fid e n tia l
Main Assembly 14 (Case Unit)
Near-end detector assembly (optional)
1. Attach the near-end detector lever to the near-end detector frame.
2. Connect the lead wire assembly’s connector to the near-end detector and attach it to the
near-end detector frame with the screw.
3. Decide whether you want to install the spacers.
The amount (A) of paper remaining (including the paper roll core) when the near-end
detector senses a paper near-end is changed by the spacers.
The amount (A) with the spacers: 3 to 4 mm (0.12 to 0.16”)
Near-end detector
lever
CBB-tite (M2x8)
[0.1 to 0.2 N • m
(1 to 2 kgf • cm)]
Near-end detector
frame
Near-end detector
Lead wire assembly
d
A