Adjusting
3-9
TM-H6000/H6000P Service Manual
Confidential
Adjusting the Platen Gap
Adjust the platen gap when you have performed any one of the followings.
Use the following steps to adjust the platen gap.
1. Connect the power supply unit to the printer. Turn on the power switch to the printer. Turn
off the power switch to the printer when the printer finishes the power on test. Remove the
power supply unit from the printer. (These steps will close the platen.)
Note:
When you are adjusting the platen gap, you must close the platen. There are instances where the
platen is open on this printer after assembly because of positioning with the gears and cams.
Therefore, you must always use these steps to close the platen.
2. Remove the ribbon cassette cover. (See page 2-37.)
3. Remove the carriage cover frame assembly. (See page 1-15.)
4. Prepare 0.45 mm and 0.50 mm thickness gauges. Insert the thickness gauges from the side of
the print head unit, as shown in the figure below.
Figure 3-8
Platen Gap Adjustment
❏
When you replaced or removed the print head unit.
❏
When you disassembled or re-assembled the TM-H6000/H6000P printer.
Summary of Contents for TM-H6000
Page 1: ...Confidential Service manual TM H6000 H6000P English 401040800 Issued Date 199 Issued by ...
Page 29: ...1 20 Troubleshooting Rev A Confidential ...
Page 69: ...Disassembly and Assembly 2 40 Rev A Confidential ...
Page 81: ...3 12 Adjusting Rev A Confidential ...
Page 83: ...Appendix A 2 Service Tools and Lubricants Rev A Confidential ...
Page 87: ...Appendix B 4 Maintenance Rev A Confidential ...
Page 225: ...I 10 Printer Handling Rev A Confidential ...
Page 227: ...Appendix J 2 Screw Types Rev A Confidential ...
Page 229: ...K 2 Parts Layout Rev A Confidential Main Circuit Board Unit solder side memory board ...