Switch Circuit
The 24V supplied from the external power source is supplied to the required locations in this
circuit. The supply power source and application are described below. The 5V system has the
same type of switch, which is also turned on and off to configure it at the same time. The circuit
is configured with a MOSFET semiconductor switch. Q44 is a 2-element MOSFET that turns the
VCC_PRW and VCC_SEN on and off.
TableD-15 Switch circuit
Type (circuit
network name)
Switch
(On/Off)
Control
Application
24VA
24VSW2
Turned on and off by Q17
GA (U30)
Thermal system power source (thermal head, paper
feed motor)
24VB
OUTH
GA (U30)
Impact head drive power source, autocutter drive
power source, MICR read circuit power source. Supplied
via TH1 when other than OUTH = HIGH status. Can only
be turned off with power switch.
24VC
24VSW1
Turned on and off by Q45
GA (U30)
Slip mechanism power source.
24V(DM)
None
None
DM power source, DK power source.
VCC
None
None
Started after power switch is turned on.
VCC-PWR
24VSW1
Turned on and off by Q44
GA (U30)
5V used by slip mechanism.
VCC-PWR2
24VSW2
Turned on and off by Q59
GA (U30)
5V for thermal system (thermal head, paper feed motor).
VCC_SEN
SEN_PWR
Turned on and off by Q44
CPU (U3)
Power source for slip system paper detection sensor.
Summary of Contents for TM-H6000
Page 1: ...Confidential Service manual TM H6000 H6000P English 401040800 Issued Date 199 Issued by ...
Page 29: ...1 20 Troubleshooting Rev A Confidential ...
Page 69: ...Disassembly and Assembly 2 40 Rev A Confidential ...
Page 81: ...3 12 Adjusting Rev A Confidential ...
Page 83: ...Appendix A 2 Service Tools and Lubricants Rev A Confidential ...
Page 87: ...Appendix B 4 Maintenance Rev A Confidential ...
Page 225: ...I 10 Printer Handling Rev A Confidential ...
Page 227: ...Appendix J 2 Screw Types Rev A Confidential ...
Page 229: ...K 2 Parts Layout Rev A Confidential Main Circuit Board Unit solder side memory board ...