Front cover open detection mechanism
The front cover open detector is located at the right side of the printer mechanism, and detects
opening and closing of the front cover. This detector consists of an LED and photo resistor. A
screening part, located on the rear of the cover, interrupts light rays when the cover is closed.
When the cover is opened, the light rays reach the photo resistor, resulting in a change in its
output level. This change in output level is used as a detection signal to determine when the
front cover is open.
Figure D-18
Clamshell mechanism
The clamshell mechanism consists of a platen lever unit, paper feed frame support shaft, and
frame fixing lever. This mechanism is used in the event of a quality problem, such as a paper
jam, and when replacing the ribbon for the endorsement printer unit (option) built into the
lower part of the platen lever unit.
Figure D-19
GND
High
+5V
GND
Low
Printer side
Front cover light interrupter unit
When light is
interrupted
When light is emitted
Signal level at point A
Paper feed frame shaft
Paper feed frame fixing
L lever (type B) assembly
Paper feed frame fixing
R lever assembly
Platen lever unit
Main frame
Summary of Contents for TM-H6000
Page 1: ...Confidential Service manual TM H6000 H6000P English 401040800 Issued Date 199 Issued by ...
Page 29: ...1 20 Troubleshooting Rev A Confidential ...
Page 69: ...Disassembly and Assembly 2 40 Rev A Confidential ...
Page 81: ...3 12 Adjusting Rev A Confidential ...
Page 83: ...Appendix A 2 Service Tools and Lubricants Rev A Confidential ...
Page 87: ...Appendix B 4 Maintenance Rev A Confidential ...
Page 225: ...I 10 Printer Handling Rev A Confidential ...
Page 227: ...Appendix J 2 Screw Types Rev A Confidential ...
Page 229: ...K 2 Parts Layout Rev A Confidential Main Circuit Board Unit solder side memory board ...