Rev. A
Disassembly and Assembly 2-15
Confidential
TM-H6000/H6000P Service Manual
14. Lubricate the lever motor reduction gear shaft.
15. Use one E-ring to attach the lever motor reduction gear to the lever motor reduction shaft.
The arrow on the lever motor deceleration gear should be facing to the outside.
16. Lubricate the inside of the sub slip feed lever shaft in two places. See Appendix G for a
lubrication diagram.)
17. Lubricate the sub slip feed shaft holder.
18. Lubricate the form stopper shaft rotating unit in two places.
19. Lubricate the main sub assembly frame and sub slip feed roller in two places where they
contact.
20. Lubricate the sub slip feed roller and main sub assembly holder.
21. Lubricate the area of contact of the stopper drive shaft and the form stopper.
22. Lubricate the lever drive cam.
Figure 2-14
23. Attach the slip B.O.F. detector assembly to the slip guide lower frame (type B) with one
screw .
24. Insert the lead wire.
689 E-ring(2.3)
666 Sub slip feed
roller assembly
614 Lever motor reduction gear
613 Lever drive motor
detector plate
616
Lever drive shaft
gear
639 Slip drive gear
Summary of Contents for TM-H6000
Page 1: ...Confidential Service manual TM H6000 H6000P English 401040800 Issued Date 199 Issued by ...
Page 29: ...1 20 Troubleshooting Rev A Confidential ...
Page 69: ...Disassembly and Assembly 2 40 Rev A Confidential ...
Page 81: ...3 12 Adjusting Rev A Confidential ...
Page 83: ...Appendix A 2 Service Tools and Lubricants Rev A Confidential ...
Page 87: ...Appendix B 4 Maintenance Rev A Confidential ...
Page 225: ...I 10 Printer Handling Rev A Confidential ...
Page 227: ...Appendix J 2 Screw Types Rev A Confidential ...
Page 229: ...K 2 Parts Layout Rev A Confidential Main Circuit Board Unit solder side memory board ...