EPSON Stylus Photo R1800/R2400
Revision B
Troubleshooting
Overview
54
At power-on
While the power-on sequence
is being executed, Fatal error
is displayed.
ASF Motor
1. Check that the Connector cable of the ASF Motor is
connected to the Relay Connector.
1. Connect the Connector cable of the ASF
Motor to the Relay Connector.
2. Using a tester, check the resistance value of the ASF
Motor.
Value of resistance : 7.0
Ω
±
10%
2. If the resistance value is abnormal, replace
the ASF Motor with a new one.
3. Check the ASF Motor connector cable for damages.
3. Replace the ASF Motor with a new one.
Relay
Connector
Cable
(for the ASF
Motor)
1. Check that the Relay Connector Cable is connected to the
Main Board Connector CN19.
1. Connect the Relay Connector Cable to the
Main Board Connector CN19.
2. Check the Relay Connector Cable for damages.
2. Replace the Relay Connector Cable with a
new one.
Table 3-12. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point
Remedy
Relay Connector
ASF Motor
CN19
Summary of Contents for R1800 - Stylus Photo Color Inkjet Printer
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 15: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 35: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 68: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 128: ...C H A P T E R 5 ADJUSTMENT ...
Page 172: ...C H A P T E R 6 MAINTENANCE ...
Page 181: ...C H A P T E R 7 APPENDIX ...
Page 196: ...EPSON Stylus Photo R1800 R2400 Revision B Appendix Circuit Diagram 196 C589 PNL circuit board ...
Page 198: ...C H A P T E R 8 STYLUSPHOTOR2400 ...