EPSON Stylus Photo R1800/R2400
Revision B
Adjustment
Adjustment
154
8.
After the Calibration Chart is printed, allow it to dry for five minutes. During
this time, check the nozzle check pattern on the chart. If there are broken
lines or missing segments, click [Print Calibration Chart again], and return
to
. If there are no broken lines or missing segments, click [Next].
Figure 5-33. Drying the Chart
9.
Connect the Calibrator to the PC and click [Color Measuring]. The color
measurement procedure screen operated by the Calibrator control plug-in
(DLL) is displayed on screen overlapping the Colorimetric Calibration Tool.
Figure 5-34. Color Measurement
10. Place the Calibrator on the calibration plate, and click [Calibrate]
Figure 5-35. Preparing the Calibrator
When there are broken lines
or missing segments
This button is enabled when
countdown is completed.
C A U T I O N
The white reference tile on the calibration plate should be
clean. Clean off any dirt with alcohol or other organic
solvent.
The calibration plate and the Calibrator are used as a
pair. Do not use a calibration plate supplied with an
another Calibrator.
Summary of Contents for R1800 - Stylus Photo Color Inkjet Printer
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 15: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 35: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 68: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 128: ...C H A P T E R 5 ADJUSTMENT ...
Page 172: ...C H A P T E R 6 MAINTENANCE ...
Page 181: ...C H A P T E R 7 APPENDIX ...
Page 196: ...EPSON Stylus Photo R1800 R2400 Revision B Appendix Circuit Diagram 196 C589 PNL circuit board ...
Page 198: ...C H A P T E R 8 STYLUSPHOTOR2400 ...