Product Description
LX-300 Service Manual
1.2.1.5 Electrical Specifications
Table 1-10. Electrical
Description
120 V Version
220-240 V Version
Rated voltage
120
220-240
Input voltage range
103.5-132
198-264
r
Rated
frequency range
50-60 Hz
Input frequency range
49.5 -60.5 Hz
Rated current
1.0 A
0.5 A
Power mnsumption
30 W (self-test in 10 cpi draft)
10 MQ, minimum
Insulation resistance
minimum
(applying 500
between
500
between
and
AC
and chassis)
1000
ma for 1 minute or
Dielectric strength
1500
for 1 minute
(between AC
and
1.2.1.6 Environmental
Conditions
Table 1-11.
Conditions
Description
Operating
Storage
Temperature
5to 35°
c
(41 - 95° (*1)
–20to 55° c (-4 - 131° (*2)
Humidity
30 to 80% RH (*1,*3)
5 to 85% RH (*2,*3)
Resistance to vibration
0.25 G, 55
(*1)
0.50 G, 55
(*2)
*1= Operating conditions must
within this range.
*2= When the printer is in the shipping container.
*3 = Without condensation.
1.2.1.7 Reliability
Printhead life:
1.2.1.8 Safety Approvals
Safety standards:
Radio frequency interference:
4000
power on hours
200 million strokes/wire (with monochrome ribbon)
100 million strokes/wire (with color ribbon)
U.S. version:
European version:
U.S. version:
European version:
UL1950 with D3,
#950 with D3
EN 60950
SETI)
FCC part 15 subpart B class B
part 3, part 30)
PUB. 22) class B
1.2.1.9 Physical Specifications
Dimensions (W x
D x H):
366 x 275 x 132 (mm) (14.4
x
10.8
x
5.20 (inches)
(without pull tractor)
Weight:
4 kg (8.8 lb.) without pull tractor