Disassembly and Assembly
3-10
ESPON FX-880/FX-1180 Service Manual
During re-assembly, note the following points:
When replacing the upper housing, seat the hooks on the upper housing in the corresponding
holes in the rear of the lower housing; then close the housing.
The release lever collar can be replaced after the upper housing has already been installed.
Upper Housing
Release Lever
Release Lever Sheet
CBB Screw (4 x 12)
CBS Screw (M3 x 6)
Control Panel
Lower Case
Control Panel FFC
Control Panel FFC
CBS Screw (M3 x 6)
Figure 3-5. Upper Housing Removal
Release Lever Collar