DISASSEMBLY AND ASSEMBLY
Rev. A
3-
19
When installing the preview motor, the cable must be twisted four times and is stored inside of the
motor frame., as shown in Figure 3-24.
When mounts the shaft holding plate A, the right side of the plate and the grounding wire for the
optical unit must be fixed by the same screw (Refer to Figure 3-26.).
Hook
CN4
CN4
Motor Junction Board
Micro Switch Board A
Screw
Figure 3-25. Micro Switch Board A Removal
ASSEMBLING POINT
Grounding
Wire From
Optical Unit
Shaft Holding Plate A
Figure 3-26. Grounding Plate A Mounting