7.8 Cancel code
Structure
Item
Byte (Hex)
Value (Hex)
Header
1
13h
Parameter counter
1
01
Parameter
1
Cancel request
The parameter <cancel code> is one byte Binary code that indicates the cancel request.
Cancel request
Code
No request
01
The status during received cancel command and initialize the printer
A1
Request
81
7.9 Job name Information
Structure
Item
Byte (Hex)
Value (Hex)
Header
1
19
Parameter counter
1
n (Max 37)
Parameter
Max 37
Job name information
The parameter <Job name information> is n bytes Binary codes.
It indicates the m1 to m5 parameter and Job name specified by JH command.
If the JH command is not send of printing job, it replies “unknown”.
Item
Byte (Hex)
Value (Hex)
Header
1
19
Parameter counter
1
0C
Parameter
0C
0000000000 “unknown”