Thermistor and Temperature Sensor Operation
Analog/Digital converters in IC104 on the MA board detect the temperatures of the Optical
Engine and Power Supply sections by means of the two Lamp Thermistors at intervals of 1
second. Based on the measurement results, the CPU controls fan operations and power supply
shutdown operations as necessary.
See Section 2.8.2 for more information on fan operation, and Section 2.9 for more information
on the LED status indicators.
2.8.2 Fan Operation
There are five cooling fans inside the projector. These fans discharge heated air produced by
the Lamp Assy., power supply unit, and ballast unit.
Figure 2-22. Fan Locations
Table 2-4. Temperature Sensors
Condition
Warning Indicator
Meaning
Normal temperature
Off
Normal operation in progress
Warning temperature
Flashes orange
If temperature rises any higher, projection
stops.
Abnormal temperature
Steady red
Overheating (no projection)
Internal error
Flashes red
Problem with fans, thermistors or temper-
ature detection circuit
Exhaust Fan
Power Supply Fan
Intake fan 1
Intake fan 2
Lamp Fan
Summary of Contents for EMP-S4
Page 1: ...Service Manual Data Projector EMP S4 ...
Page 13: ...Chapter 1 Product Specifications ...
Page 25: ...1 13 EMP S4 SEIKO EPSON Revision B 1 5 External Views Figure 1 8 External Dimensions Unit mm ...
Page 26: ...1 14 EMP S4 SEIKO EPSON Revision B Figure 1 9 External Dimensions Unit Inch ...
Page 27: ...Chapter 2 Theory of Operation ...
Page 49: ...Chapter 3 Troubleshooting ...
Page 63: ...Chapter 4 Disassembly Assembly ...
Page 97: ...Chapter 5 Appendix ...
Page 102: ...5 6 EMP S4 SEIKO EPSON Revision B ...