maxon motor control
EPOS Application Note: Interpolation Position Mode
EPOS Positioning Controller
Edition December 2008 / Subject to change
maxon motor control
15
Name
Interpolation time index
Index
0x60C2
Subindex
0x01
Type
INTEGER8
Access
RW
Default Value
-3
Value range
-3
-3
PDO Mapping
No
Description
This object indicates the configured interpolation cycle time. The interpolation time period (sub-index 0x01) value is
given in 10
(interpolation time index)
s(econds). The interpolation time index (sub-index 0x02) is dimensionless.
3.6.7
Interpolation data configuration
Name
Interpolation data configuration
Index
0x60C4
number of entries
0x06
Name
Maximum buffer size
Index
0x60C4
Subindex
0x01
Type
UNSIGNED32
Access
RO
Default Value
-
Value range
64
64
PDO Mapping
No
Description
This object provides the maximal buffer size and is given in interpolation data records.
Name
Actual buffer size
Index
0x60C4
Subindex
0x02
Type
UNSIGNED32
Access
RO
Default Value
64
Value range
0
64
PDO Mapping
Yes
Description
This object provides the actual free buffer size and is given in interpolation data records.