3
A circuit breaker should be used between the battery and the inverter/charger; the
circuit breaker's value should be twice the inverter/charger rated input current.
DO NOT put the inverter/charger close to the flooded lead-acid battery because
the terminals' sparkle may ignite the hydrogen released by the battery.
The AC output port is only connected to the load. It is strictly forbidden to connect
other power sources or utilities. Otherwise, the damage will be caused to the
inverter/charger. Also, turn off the inverter/charger before any installation.
Both utility input and AC output are of high voltage, do not touch the wiring
connection to avoid electric shock.
7. Safety cautions for inverter/charger operation:
When the inverter/charger is working, its heat sink and casing will generate a lot
of heat; the temperature would be very high. Please do not touch it.
When the inverter/charger is working, please do not open the inverter/charger
cabinet to operate.
When eliminating the faults or disconnecting the DC input, turning off the
inverter/charger's switch, then carry out the operation after the LCD screen is
completely OFF.
8. The dangerous operations which would cause electric arc, fire, or explosion:
Touch the wire end that hasn't been insulation treated and maybe electriferous.
Touch the wiring copper row, terminals, or internal devices that may be
electriferous.
The power cable connection is loose.
Screw or other spare parts inadvertently falls into the inverter/charger.
Incorrect operation by untrained non-professional or technical personnel.
Once an accident occurs, it must be handled by professional and technical
personnel. Any incorrect operation would cause a more severe accident.
9. Safety cautions for stopping the inverter/charger
Firstly turn off the breakers on the utility input side and AC output side, then turn
off the DC switch;
After the inverter/charger stop working for ten minutes, the internal conductive
devices could be touched;
The inverter/charger can be restarted after removing the faults which may affect
its safety performance;