Annex I Conversion Efficiency Curves

Illumination Intensity: 1000W/m

2     

Temperature: 25ºC

   

Model:

TRIRON1206N

1.

Solar Module MPP Voltage(17V, 34V) / Nominal System Voltage(12V)

2.

Solar Module MPP Voltage(34V) / Nominal System Voltage(24V)

Summary of Contents for SolarV TRIRON Series

Page 1: ......

Page 2: ...ttempt to repair the controller x Mount the controller indoors Prevent exposure to the elements and do not allow water to enter the controller x Install the controller in a well ventilated place The c...

Page 3: ...7 2 3 Wire Size 9 2 4 Mounting 10 3 Modules installation 14 4 Module Introduction 16 4 1 Display Module 16 4 1 1 Display Basic1 DB1 16 4 1 2 Display Standard1 DS1 17 4 1 3 Display Standard 2 DS2 21 4...

Page 4: ...1 Supported battery types 30 5 1 2 Local setting 30 5 1 3 Remote Setting 34 5 2 Load working modes 37 5 2 1 LCD setting 37 5 2 2 RS485 communication setting 39 6 Others 40 6 1 Protection 40 6 2 Troubl...

Page 5: ...lifecycle improve performance and support electronic protection functions The overcharging and over discharging protections minimize damages to components caused by incorrect installation or system fa...

Page 6: ...DC power through the dual USB output interface to charge electronic devices c For the BCV FCV LVD and LVR users can modify them on the local controller when the battery type is USE 1 2 Characteristics...

Page 7: ...without any other modules Model System voltage Max PV open circuit voltage Rated charge discharge current Picture TRIRON1206N 12 24VDC 60V 10A TRIRON2206N 12 24VDC 60V 20A TRIRON1210N 12 24VDC 100V 10...

Page 8: ...troller communicates with the inverter Display Standard 2 DS2 Indicators PV battery load working status Buttons View or set the parameters LCD PV display voltage current generated energy Power Battery...

Page 9: ...ers via the LCD Relay interface Remotely control the inverter ON OFF NOTE The module can t connect the accessories Accessory 3 81 2P terminal Relay COM Slave RCS RS485 interface Connect to PC or phone...

Page 10: ...Cover CCV No interface CAUTION The controller must be powered off for 1 minute when the user replaces the display modules or interface modules 1 4 Naming rules Copyright 2022 SolarV GmbH All rights r...

Page 11: ...se cable clamps to secure cables and prevent them from swaying in mobile applications y Lead acid and lithium batteries are recommended other kinds please refer to the battery manufacturer y The batte...

Page 12: ...erature 25 Air Mass1 5 TRIRON1210N 2210N 3210N 4210N System voltage 36 cell Voc 23V 48 cell Voc 31V 54 cell Voc 34V 60 cell Voc 38V Max Best Max Best Max Best Max Best 12V 4 2 2 1 2 1 2 1 24V 4 3 2 2...

Page 13: ...When PV modules are connected in series the Isc equals the PV module Isc When PV modules are connected in parallel the Isc equals the sum of the PV module s Isc The Isc of the PV array must not excee...

Page 14: ...TION The wire size is only for reference Suppose there is a long distance between the PV array the controller and the battery In that case larger wires can be used to reduce the voltage drop and impro...

Page 15: ...e Figure 2 2 Schematic of wiring diagram The controller shall be installed in a place with sufficient airflow through the controller radiators and a minimum clearance of 150 mm from the upper and lowe...

Page 16: ...the TRIRON series is a common negative controller the negative poles of the PV array battery and load can be grounded together CAUTION The controller can also be used in a common positive system In th...

Page 17: ...ery indicator s status the controller operates normally when the indicator is lit in green Connect the fast acting fuse and circuit breaker of the load and PV array Then the system will work in prepro...

Page 18: ...14 3 Modules installation Copyright 2022 SolarV GmbH All rights reserved...

Page 19: ...15 Copyright 2022 SolarV GmbH All rights reserved...

Page 20: ...en Fast flashing 4Hz PV Over voltage Green On Solid Normal Green Slowly flashing 1Hz Full Green Fast flashing 4Hz Overvoltage Orange On Solid Under voltage Red On Solid Over discharged Red Slowly flas...

Page 21: ...ndicators are ON 100 Indicator is OFF Indicator is on Solid Indicator is slowly flashing x Load status Battery Capacity Level Green on solid The load is ON Green OFF The load is OFF 3 Button In the ma...

Page 22: ...ameters Press the button to confirm the setting parameters or exit the setting mode automatically after 10s 3 Interface Note The display screen can be viewed clearly when the angle between the end use...

Page 23: ...interface Press the button to cycle display the following interfaces 3 Load parameters x Combination of the DS1 and RCM modules To connect the system with the inverter refer to 4 2 4 Display Voltage...

Page 24: ...nterface until the value flashes Step 2 Press the button to clear the generated energy Switch the battery temperature unit Long press the button under the battery temperature interface Battery type St...

Page 25: ...ad working modes 4 1 3 Display Standard 2 DS2 1 Indicator Indicator Color Status Instruction Green On Solid PV charges the battery with a low current Green OFF 1 No sunlight 2 Connection Error 3 Low P...

Page 26: ...time Press the button BATT browsing interface Cursor displacement during setting Press the button and hold 5s Setting the battery type battery capacity level and temperature unit Press the button 1 In...

Page 27: ...on Information Icon Information Day Not charging Not discharging Night Charging Discharging 1 PV parameters Display Voltage Current Power Generated Energy 2 Battery parameters Display Voltage Current...

Page 28: ...s the button to browse the battery parameters Then press the button to enter the battery parameters setting interface Step 2 Long press the button to enter the battery type interface Step 3 Press the...

Page 29: ...he or button to set the battery capacity Step 5 Press the button to confirm 3 Temperature unit Operation Step 1 On the initial interface press the button to browse the battery parameters Then press th...

Page 30: ...the PV parameters setting interface Step 2 Long press the button to enter the LCD cycle time interface and the cycle time flashes Step 3 Hold the button and the button for 5 seconds to clear the accum...

Page 31: ...Instruction 1 5VDC 5V 200mA 5 RS485 A RS485 A 2 5VDC 6 RS485 A 3 RS485 B RS485 B 7 GND Power GND 4 RS485 B 8 GND 4 2 2 Double USB USB1 USB output interface Charging for phone pad etc The Max charging...

Page 32: ...unication mode i e with a combination of the RCM and DS1 DS2 modules the information of the inverter to be supplied by our company can be displayed by the DS1 DS2 module See the following figure Relay...

Page 33: ...with a combination of the RCS and DS1 DS2 modules the controller s information can be displayed by the DS1 DS2 module Relay interface It shall connect the controller s relay in parallel with the inve...

Page 34: ...ery type Detailed operations of entering the USE battery type are shown in the following table Content DS1 module operation steps DS2 module operation steps Enter the USE battery type 1 Press the butt...

Page 35: ...the button to enter the battery type interface again on the battery parameters setting interface 4 Press the or button to select the battery type USE Step2 Set the battery parameters on the local devi...

Page 36: ...7 Low voltage disconnect voltage LVD 11 1V 9 17 Lithium battery protection enable LEN NO YES NO Press the button to modify the switch status Note It exists automatically from the current interface aft...

Page 37: ...arging voltage Equalize charging voltage BCV 0 2V voltage level Boost charging voltage Boost charging voltage Boost reconnect charging voltage FCV 0 6V voltage level FCV 0 6V voltage level FCV 0 1V vo...

Page 38: ...xternal WiFi module Connect the controller to an external WIFI module through a standard network cable End users can set the voltage parameters by the APP after selecting the battery type as USE Refer...

Page 39: ...0V 16 0V 9 17V Charging limit voltage 15 0V 15 0V 15 0V 9 17V Over voltage reconnect voltage 15 0V 15 0V 15 0V 9 17V Equalize charging voltage 14 6V 14 8V 9 17V Boost charging voltage 14 4V 14 2V 14 6...

Page 40: ...voltage disconnect voltage 14 8V 29 6 V 12 8 V 25 6 V 29 8 V 9 17 V Charging limit voltage 14 6 V 29 2 V 12 6 V 25 2 V 29 4 V 9 17 V Over voltage reconnect voltage 14 6 V 29 2 V 12 5 V 25 0 V 29 1 V...

Page 41: ...ing Limit Voltage D 8QGHU 9ROWDJH DUQLQJ 5HFRQQHFW 9ROWDJH 8QGHU 9ROWDJH DUQLQJ 9ROWDJH LVFKDUJLQJ Limit Voltage E Boost Reconnect Charging voltage Low Voltage Reconnect Voltage F RZ 9ROWDJH LVFRQQHFW...

Page 42: ...will be on for 1 hour before sunrise 102 The load will be on for 2 hours from sunset 202 The load will be on for 2 hours before sunrise 103 113 The load will be on for 3 13 hours from sunset 203 213...

Page 43: ...F of the load via the button or remote commands e g APP or PC software y Light ON OFF y Light ON Timer y Time Control Control the load ON OFF time by setting the real time clock 2 Load mode settings S...

Page 44: ...times the rated charging power Night Reverse Charging Prevents the battery from discharging through the PV module at night Battery Reverse Polarity Fully protected against reverse battery polarity no...

Page 45: ...rom Night to Day nighttime 3 hours Controller Overheating The controller can detect the temperature inside the battery through an optional remote sensor The controller stops working when its temperatu...

Page 46: ...Red on solid DB1 Battery indicator Red slowly flashing Battery Overheating The controller will automatically turn the system off But while the temperature declines below 55 C the controller will resum...

Page 47: ...ght day cycle night time 3 hours Load Short Circuit Fault code E001 only DS2 Check the load connection and clear the fault Restart the controller Wait for one night day cycle night time 3 hours x Inve...

Page 48: ...e connections y Check and confirm that LED is consistent with what is required Pay attention to any troubleshooting or error indication Take corrective action if necessary y Confirm that all the syste...

Page 49: ...2V 108V Rated charge power 130W 12V 260W 24V 260W 12V 520W 24V 130W 12V 260W 24V 260W 12V 520W 24V 390W 12V 780W 24V 520W 12V 1040W 24V 390W 12V 780W 24V 520W 12V 1040W 24V Self consumption P 9 P 9 P...

Page 50: ...meters Item TRIRON1206N TRIRON1210N TRIRON2206N TRIRON2210N TRIRON3210N TRIRON3215N TRIRON4210N TRIRON4215N Dimension LxWxH 180 8x135x47 3mm 216x150x56 7mm 238 3x158x62 7mm 256 8x183x66 7mm Mounting s...

Page 51: ...ts reserved Annex I Conversion Efficiency Curves Illumination Intensity 1000W m2 Temperature 25 C Model TRIRON1206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Vol...

Page 52: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON1210N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V Nominal System Voltage 24V...

Page 53: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON2206N 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V Nominal System Voltage 24V...

Page 54: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON2210N 1 Solar Module MPP Voltage 17V 34V 51V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 55: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON3210N 1 Solar Module MPP Voltage 17V 34V 51V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 56: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON3215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V...

Page 57: ...Copyright 2022 SolarV GmbH All rights reserved Model TRIRON4210N 1 Solar Module MPP Voltage 17V 34V 51V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Page 58: ...H All rights reserved Model TRIRON4215N 1 Solar Module MPP Voltage 17V 34V 68V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 68V 102V Nominal System Voltage 24V Any changes without prior n...

Page 59: ......

Reviews: