31
select the battery type as F04. And then, press the
button to confirm and go back to the battery voltage
interface automatically.
3) Long-press the
button to enter the battery-type
interface again on the battery voltage interface.
4) Press the
button to select the battery type as
“USE.”
the
button to enter the battery-type interface.
2) Press the
or
button to select the battery
type, such as select the battery type as F04. And then
press the
button to confirm. Continue to press the
button twice or wait for 10S of no-operation to
automatically go back to the battery parameters setting
interface.
3) Long-press the
button to enter the battery-type
interface again on the battery parameters setting
interface.
4) Press the
or
button to select the battery
type “USE.”
Step2: Set the battery parameters on the local device.
Under the "USE" interface, the battery parameters that can be local set are shown in the table
below:
Parameters
Default
Range
DS1 module operation steps
DS2 module operation steps
System
voltage level
(SYS)
12VDC
12/24VDC
1) Under the "USE" battery type, press
the
button to enter the “SYS” interface.
2) Press
the
button again to display the
current “SYS” value.
3) Press the
button to modify the parameter.
1) Under the "USE" battery type, press
the
button to enter the “SYS” interface.
2) Press
the
button again to display the
current “SYS” value.
3) Press the
or
button to modify
32
4) Press
the
button to confirm and enter the
next parameter.
the parameter.
4) Press
the
button to confirm and
enter the next parameter.
Boost charging
voltage (BCV)
14.4V
9
—
17
5) Press
the
button again to display the
current voltage value.
6) Press the
button to modify the
parameter(short press to increase 0.1V, long
press to decrease 0.1V).
7) Press
the
button to confirm and enter the
next parameter.
5) Press
the
button again to display the
current voltage value.
6) Press the
or
button to modify
the parameter(press
button to
increase 0.1V, press
button to
decrease 0.1V).
7) Press
the
button to confirm and
enter the next parameter.
Float charging
voltage (FCV)
13.8V
9
—
17
Low voltage
reconnect
voltage (LVR)
12.6V
9
—
17
Low voltage
disconnect
voltage (LVD)
11.1V
9
—
17
Lithium battery
protection
enable (LEN)
NO
YES/NO
Press the
button to modify the switch status.
Note: It exists automatically from the current
interface after no operation of more than 10S.
Press the
or
button to modify the
switch status.
Note: It exists automatically from the
current interface after no operation of more
than 10S.
The SYS value can only be modified under the non-lithium "USE" type. The SYS value can be modified if the battery type is Sealed, Gel, or
Flooded before entering the "USE" type. The SYS value cannot be modified if it is a lithium battery type before entering the "USE" type.
Only the above battery parameters can be set on the local controller, and the remaining battery parameters follow the following logic. The
voltage level of the 12V system is 1, and the voltage level of the 24V system is 2.