Digitax ST User Guide
151
Issue Number: 5
Parameter
Range(
Ú
)
Default(
Ö
)
Type
12.01
Threshold detector 1 output
OFF (0) or On (1)
RO Bit
NC PT
12.02
Threshold detector 2 output
OFF (0) or On (1)
RO Bit
NC PT
12.03
Threshold detector 1 source
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.04
Threshold detector 1 level
0.00 to 100.00 %
0.00
RW Uni
US
12.05
Threshold detector 1
hysteresis
0.00 to 25.00 %
0.00
RW Uni
US
12.06
Threshold detector 1 output
invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
12.07
Threshold detector 1
destination
Pr
0.00
to
21.51
Pr
0.00
RW Uni DE
PT US
12.08
Variable selector 1 source 1
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.09
Variable selector 1 source 2
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.10
Variable selector 1 mode
Select input 1 (0), select input 2 (1), add (2),
subtract (3), multiply (4), divide (5),
filter (6), linear ramp (7), absolute value (8),
powers (9), sectional control (10),
external rectifier monitor (11)
Select input 1 (0)
RW Uni
US
12.11
Variable selector 1
destination
Pr
0.00
to
21.51
Pr
0.00
RW Uni DE
PT US
12.12
Variable selector 1 output
±100.00 %
RO Bi
NC PT
12.13
Variable selector 1 source 1
scaling
±4.000
1.000
RW Bi
US
12.14
Variable selector 1 source 2
scaling
±4.000
1.000
RW Bi
US
12.15
Variable selector 1 control
0.00 to 100.00 s
0.00
RW Uni
US
12.23
Threshold detector 2 source
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.24
Threshold detector 2 level
0.00 to 100
.00 %
0.00
RW Uni
US
12.25
Threshold detector 2
hysteresis
0.00 to 25.00 %
0.00
RW Uni
US
12.26
Threshold detector 2 output
invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
12.27
Threshold detector 2
destination
Pr
0.00
to
21.51
Pr
0.00
RW Uni DE
PT US
12.28
Variable selector 2 source 1
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.29
Variable selector 2 source 2
Pr
0.00
to
21.51
Pr
0.00
RW Uni
PT US
12.30
Variable selector 2 mode
Select input 1 (0), select input 2 (1), add (2),
subtract (3), multiply (4), divide (5),
filter (6), linear ramp (7), absolute value (8),
powers (9), sectional control (10),
external rectifier monitor (11)
Select input 1 (0)
RW Uni
US
12.31
Variable selector 2
destination
Pr
0.00
to
21.51
Pr
0.00
RW Uni DE
PT US
12.32
Variable selector 2 output
±100.00 %
RO Bi
NC PT
12.33
Variable selector 2 source 1
scaling
±4.000
1.000
RW Bi
US
12.34
Variable selector 2 source 2
scaling
±4.000
1.000
RW Bi
US
12.35
Variable selector 2 control
0.00 to 100.00 s
0.00
RW Uni
US
12.40
Brake release indicator
OFF (0) or On (1)
RO Bit
NC PT
12.41
Brake controller enable
dis (0), rEL (1), d IO (2), USEr (3)
dis (0)
RW Txt
US
12.43
Lower current threshold
0 to 200 %
10
RW Uni
US
12.45
Brake apply speed
0 to 200 rpm
5
RW Bit
US
12.46
Brake apply speed delay
0.0 to 25.0 s
1.0
RW Uni
US
12.47
Post brake release delay
0.0 to 25.0 s
1.0
RW Uni
US
12.48
Brake apply delay
0.0 to 25.0 s
1.0
RW Uni
US
12.49
Enable position controller
during brake release
OFF (0) or On (1)
OFF (0)
RW Bit
US
The brake control functions are provided to allow well co-ordinated operation of an external brake with the drive. While both hardware
and software are designed to high standards of quality and robustness, they are not intended for use as safety functions, i.e. where a
fault or failure would result in a risk of injury. In any application where the incorrect operation of the brake release mechanism could
result in injury, independent protection devices of proven integrity must also be incorporated.
WARNING
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save