128
Digitax ST User Guide
Issue Number: 5
Parameter
Range(
Ú
)
Default(
Ö
)
Type
4.01
Current magnitude
{
0.12
}
0 to DRIVE_CURRENT_MAX A
RO Uni FI NC PT
4.02
Active current
±DRIVE_CURRENT_MAX A
RO Bi
FI NC PT
4.03
Torque demand
±TORQUE_PROD_CURRENT_MAX %
RO Bi
FI NC PT
4.04
Current demand
±TORQUE_PROD_CURRENT_MAX %
RO Bi
FI NC PT
4.05
Motoring current limit
0 to MOTOR1_CURRENT_LIMIT_MAX %
300.0
RW Uni
RA
US
4.06
Regen current limit
0 to MOTOR1_CURRENT_LIMIT_MAX %
300.0
RW Uni
RA
US
4.07
Symmetrical current limit
{
0.06
}
0 to MOTOR1_CURRENT_LIMIT_MAX %
300.0
RW Uni
RA
US
4.08
Torque reference
±USER_CURRENT_MAX %
0.00
RW Bi
US
4.09
Torque offset
±USER_CURRENT_MAX %
0.0
RW Bi
US
4.10
Torque offset select
OFF (0) or On (1)
OFF (0)
RW Bit
US
4.11
Torque mode selector
{
0.14
}
0 to 4
0
RW Uni
US
4.12
Current demand filter 1
{
0.17
}
0.0 to 25.0 ms
0.0
RW Uni
US
4.13
Current controller Kp gain
{
0.38
}
0 to 30,000
200V drive: 75
400V drive: 150
RW Uni
US
4.14
Current controller Ki gain
{
0.39
}
0 to 30,000
200V drive: 1000
400V drive: 2000
RW Uni
US
4.15
Thermal filter
{
0.45
}
0.0 to 3000.0
20.0
RW Uni
US
4.16
Thermal protection mode
0 to 1
0
RW Bit
US
4.17
Reactive current
±DRIVE_CURRENT_MAX A
RO Bi
FI NC PT
4.18
Overriding current limit
±TORQUE_PROD_CURRENT_MAX %
RO Uni
NC PT
4.19
Overload accumulator
0 to 100.0 %
RO Uni
NC PT
4.20
Percentage load
±USER_CURRENT_MAX %
RO Bi
FI NC PT
4.22
Inertia compensation enable
OFF (0) or On (1)
OFF (0)
RW Bit
US
4.23
Current demand filter 2
0.0 to 25.0 ms
0.0
RW Uni
US
4.24
User current maximum
scaling
0.0 to TORQUE_PROD_CURRENT_MAX %
300.0
RW Uni
RA
US
4.25
Low speed thermal protection
mode
OFF (0) or On (1)
OFF (0)
RW Bit
US
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save