132
Digitax ST User Guide
Issue Number: 5
Parameter
Range(
Ú
)
Default(
Ö
)
Type
5.01
Output frequency
{
0.11
}
±SPEED_REF_MAX rpm
RO Bi
FI NC PT
5.02
Output voltage
0 to AC_VOLTAGE_MAX V
RO Uni FI NC PT
5.03
Output power
±POWER_MAX kW
RO Bi
FI NC PT
5.05
D.C bus voltage
0 to +DC_VOLTAGE_MAX V
RO Uni FI NC PT
5.07
Motor rated current
{
0.46
}
0 to RATED_CURRENT_MAX A
Drive rated current [
11.32
]
RW Uni
RA
US
5.08
Rated speed
0.00 to 40,000.00 rpm
3,000.00
RW Uni
US
5.09
Rated voltage
{
0.44
}
0 to AC_VOLTAGE_SET_MAX V
200 V drive: 230
400 V drive: EUR> 400, USA> 460
RW Uni
RA
US
5.11
Number of motor poles
{
0.42
}
Auto to 120 Pole (0 to 60)
6 POLE (3)
RW Txt
US
5.12
Autotune
{
0.40
}
SV> 0 to 6
0
RW Uni
NC
5.14
Action on enable
nonE (0), Ph EnL (1), Ph Init (2)
nonE(0)
RW Txt
US
5.17
Motor stator resistance
0.000 to 65.000 x 10
Ω
0.0
RW Uni
RA
US
5.18
Maximum switching
frequency
{
0.41
}
0 to 4 (3, 4, 6, 8, 12 kHz)
2 (6 kHz)
RW Txt
RA
US
5.21
Field gain reduction
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.22
High speed servo mode
enable
OFF (0) or On (1)
0
RW Bit
US
5.24
Transient inductance (
σ
L
s
)
0.000 to 500.000 mH
0.000
RW Uni
RA
US
5.26
High dynamic performance
enable
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.31
Voltage controller gain
0 to 30
1
RW Uni
US
5.32
Motor torque per amp, K
t
0.00 to 500.00 N m A
-1
1.60
RW Uni
US
5.33
Motor volts per 1,000 rpm, K
e
0 to 10,000 V
98
RW Uni
US
5.35
Disable auto switching
frequency change
OFF (0) or On (1)
OFF (0)
RW Bit
US
5.36
Motor pole pitch
0 to 655.35 mm
0.00
RW Uni
US
5.37
Actual switching frequency
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5), 6 rEd (6),
12 rEd (7)
RO Txt
NC PT
5.38
Minimal movement phasing test angle
0.0 to 25.5
°
5.0
RW Uni
US
5.39
Minimal movement phasing
test pulse length
0 to 3
0
RW Uni
US
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save