Therefore, should the RCD be released dur-

ing heat-up, the electrical installation must be 

checked. 

Installation of the sauna heater and control 

unit must be undertaken only by an author-

ized electrician. Without a documented proof 

of such installation a warranty is generally void.

Special advice

By installation of sauna heaters, please pay at-

tention to the DIN VDE 0100 part 703 or similar 

locally applicable national safety regulations !

The DIN standard makes the following state-

ment valid in your newest expenditure, since 

February 2006, paragraph 703.412.05; Quota-

tion:

The additional must be planned for all electric 

circuits of the Sauna by one or more fault cur-

rent protection device (RCDs) with a calculation 

difference stream not more largely than 30 mA, 

excluded of it is Sauna heating. 

The EN 60335-1 DIN (VDE 0700 part 1):2012-10 

states the following in paragraph 13.2; quote:

The leakage current may not exceed the follow-

ing values during operation:

- for stationary heaters of protection class I 0,75 

mA; or 0,75 mA each kW input of the appliance, 

depending on the higher value, at a maximum 

value of 5 mA.

If the appliance is equipped with a protective 

device for leakage current (RCD), please pay at-

tention to the fact that no other electrical units 

will be protected by this RCD.

Under current manufacturing technology, it is 

not reasonable to use heating elements for sau-

na heaters which do not collect moisture from 

the surrounding air. It is therefore possible that 

a little bit of moisture from the surrounding air 

may reach the magnesium-oxide filling in the 

heating elements during transport or storage 

and may cause the RCD to release.

In this case the oven must be heated up under 

supervision of an expert, during which the PE 

conductor is not connected. After about 10 

minutes, when moisture has evaporated from 

the heating elements, the oven must be recon-

nected to the PE conductor!

If the sauna heater is not in use for a significant 

period of time, we recommend running it every 

6 weeks, so as to avoid moisture concentrating 

in the heating elements.

Summary of Contents for Moment W

Page 1: ...VATIVE SAUNA TECH NOLOGY IPx4 Made in Germany Druck Nr 29345183 15 21 EOS Moment Control W D Montage und Gebrauchsanweisung Assembly and operating instruction EN RU Saunaheizger t Sauna heating applia...

Page 2: ...2 Deutsch 3 English 21 39...

Page 3: ...5 Hinweis zum Elektroanschluss 7 Lieferumfang 8 Technische Daten 8 Anschlussbeispiel 400 V 3N AC 9 Montage 10 Mindestabst nde 10 Inbetriebnahme und Bedienung 14 Sicherheitsabschaltung 15 Saunasteine 1...

Page 4: ...peratur werte entstehen und dort auch die Tempera turf hler und Sicherheitsbegrenzer nach den Angaben der Steuerger te Montageanleitung anzubringen sind Beim ersten Aufheizen kann es zu einer leichten...

Page 5: ...VDE 0100 Teil 703 2006 2zubeachten Saunaheiz und Steuerger t d rfen nur in Saunakabinen aus geeignetem harz armen und unbehandeltem Material z B Nordische Fichte verwendet werden In der Saunakabine da...

Page 6: ...nschlussleitung und die geeignete Kabinengr e im Verh ltnis zur An schlussleistung in kW entnehmen Sie der Tabelle Technische Daten Bei der Montage des Saunaheizger tes ist darauf zu achten dass der s...

Page 7: ...ts in dem Wandelement mit der Zuluft ffnung Leerrohre f r die Kabelverle gung eingef gt Sollten in Ihrer Kabine keine Leerrohre vorhan den sein bohren Sie unmittelbar neben dem Saunaheizger t dort wo...

Page 8: ...H x B x T 64 x 44 x 33 cm F r Kabinenvolumen 9 14 m Mindestma der Be und Entl ftung 35 x 6 cm Gewicht ohne Steine und Verpackung 13 5 kg Steinf llung 15 kg nicht im Lieferumfang enthalten Verbindung N...

Page 9: ...ussplan sowiedieVorschriftendes rtlichenEVU TAB2000 unddesVDEbeachten Achtung Bauseitig muss in Ofenzuleitung eine ausreichende Absicherung und ein Netztrennschalter installiert werden 400 V 3N AC 5 x...

Page 10: ...lichen waagerechten Abst ndezwischenHeizger tundKabinenwand sowieOfenschutz Liegebank und anderen brennbaren Materialien entnehmen Sie bitte Abb 1 Achtung StellenSiesicher dassdieMindestabst ndeeingeh...

Page 11: ...herung nach unten entnehmen Die beigef gten Spanplattenschrauben gem Abb 3 mittig ber der Lufteintritts ffnung an der Kabinenwand befestigen Hierbei mu zum Einh ngen des Saunaheizger tes ein Abstand v...

Page 12: ...uben verschlie en Achten Sie hierbei darauf dass der Deckel so weit wie m glich unter den Rand des Anschlusskastens geschoben wird Abb 7 Abb 5 Anschlussleitung nach Schaltplan anschlie en Ein Schaltpl...

Page 13: ...Seiten mit den Schl ssell chern zum Einh ngen immer in der richtigen Position zur Au enseite des Saunaheizger tes hin befinden Jetzt k nnen Sie das Saunaheizger t mit den Schl ssell chern in die berei...

Page 14: ...unterschiede zwischen der Decke und dem unteren Bereich Hinzukommt dassvieleBimetall Thermometer Wandanzeige sehrtr gereagieren sodassteilweise erst nach ca einer Stunde die wirkliche Temperatur angez...

Page 15: ...aubendreher zur ck bis Sie einen Schaltpunkt versp ren Abb 10 Der STB befindet sich nun wieder in seiner funktionsf higen Ausgangsposition Sollte der STB nach Inbetriebnahme wieder ausl sen muss das G...

Page 16: ...steine wieder ausreichend erhitzt ACHTUNG Geben Sie dem Aufgusswasser nie mehr Aufgussmittel oder therische le bei als nach Angaben des Herstellers angegeben Verwenden Sie niemals Alkohol oder unver d...

Page 17: ...d es k nnen unzul ssige Tempe raturen auftreten Reinigen bzw Entkalken Sie die Ger te bei Be darf Bei eventuell auftretenden M ngeln oder Verschlei spuren wenden Sie sich an Ihren Saunah ndler oder di...

Page 18: ...esen FI Schalter ab gesichert werden Nach dem heutigen Stand der Technik ist es nicht sinnvoll dampfdichte Rohrheizk rper f r Sauna fen einzusetzen Es kann vorkommen dass die Magnesiumoxidf llung der...

Page 19: ...ycling Bitte diese Adresse zusammen mit der Montageanwei sung gut aufbewahren Damit wir Ihre Fragen schnell und kompetent beantwor ten k nnen geben Sie uns immer die auf dem Typen schild vermerkten Da...

Page 20: ...kte sind f r den St ckgut versand Palette konzipiert Wir weisen an dieser Stelle ausdr cklich darauf hin dass unsereVerpackungen nicht f r den Einzelversand per Paketdienst geeignet sind F r Sch den d...

Page 21: ...connections 25 Scope of delivery 26 Technical data 26 Connection example 400 V 3N AC 27 Sauna heater installation 28 Minimum clearances 28 Commissioning First use 32 Safety cut off 33 Sauna stones 34...

Page 22: ...he goods or you should contact the company that shipped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater an...

Page 23: ...low resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each sauna cabin The...

Page 24: ...floor On heaters with bases this clearance is maintained via the base or legs of the device The sauna heater may not be placed on a floor made of easily flammable material laminate synthetic flooring...

Page 25: ...the air intake If no empty ducts are available in your cabin drill a sufficiently sized hole in the cabin wall directly next to the place where the cable exits the sauna heater and guide this cable o...

Page 26: ...onnection 400 V 3N AC 50 Hz Fuse protection 3 x 16 A Equipment size H x W x D 64 x 44 x 33 cm For sauna cabin size 9 14 m Min size air supply and duct vent 35 x 6 cm Weight without stones and packing...

Page 27: ...f the local power supplier TAB 2000 and the legal norms Caution An adequate fuse and a mains circuit breaker must be installed in the stove s power supply line on site 400 V 3N AC 5 x 1 5 max 10 m 6 0...

Page 28: ...ty gaps between the heater and the cabin wall or the safety guard rail bench or other flammable materials must be not smaller as indicated in Fig 1 Attention Make sure to observe the safety gaps Risk...

Page 29: ...ve the lock by pulling downwards Attach the enclosed screws in the centre of the cabin wall above the air intake as shown in Fig 3 There must be a clearance of approx 2 mm between the screw head and t...

Page 30: ...ews Ensure that the cover panel is pushed under the edge of the terminal box as far as possible Fig 7 Fig 5 Connect the power cable as shown in the wiring diagram There is a wiring diagram attached on...

Page 31: ...with the keyholes for attachment are always in the right position toward the outside of the sauna heater Now you can hook the keyholes of the sauna heater onto the screws that are screwed into the ca...

Page 32: ...evelopmentandstability Furthermoreconsiderabledifferencesbetweenthetemperaturesaround the ceiling and in the lower zones are very typical One should also consider that conventional sauna thermometers...

Page 33: ...ce a click see fig 10 The limiter is now reset and is the standard working position In the case the STB limiter releases again after the heater is switched on please let the heater be checked by a spe...

Page 34: ...ain Attention Neveraddmoreessencesorvolatileoilsthan advisedonthepackaging Neverusealcohol or undiluted concentrates Caution Fire hazard Sauna rocks Please be sure to note Do not insert sauna rocks to...

Page 35: ...ded Refer to your sauna supplier or directly to the manufacturer in case of defects or signs of wear and tear Only use original manufacturer s replacement parts which can be obtained from your suppli...

Page 36: ...ing values during operation for stationary heaters of protection class I 0 75 mA or 0 75 mA each kW input of the appliance depending on the higher value at a maximum value of 5 mA If the appliance is...

Page 37: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Page 38: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Page 39: ...39 RU 40 40 41 43 45 45 46 47 47 51 52 53 54 55 56...

Page 40: ...40 RU DIN EN ISO 9001 2015 110 C 30 40 C 110 C 20 25 85 C 80 90 C 76 C...

Page 41: ...41 RU 8 VDE 0100 49 DA 6 VDE 0100 703 2006 2 5 10...

Page 42: ...42 RU DIN EN VDE 0100 T 703 40 170 C...

Page 43: ...43 RU 76 C...

Page 44: ...44 RU...

Page 45: ...45 RU 1 6 5 x 25 4 4 2 x 9 5 6 M 4 x 12 1 3 6 7 5 6 6 9 0 400 3 50 3 x 16 A 64 x 44 x 33 9 14 35 x 6 13 5 15 5 x 1 5 max 10 0 75 40 100 C 22...

Page 46: ...500 W 9 0 kW 3x 3000 W L1L2L3 N 5 x 2 5 Leuchte Absicherung Hauptschalter Verteilerdose bauseitige Installation L1 A1 A2 A3 L2 L3 N N B1 B2 B3 Thermostat M N PE Zeitschaltuhr timer Thermostat reset A1...

Page 47: ...47 RU 1 90 90 1 1 2 2 8 cm 33 cm 8 cm 44 cm 8 cm...

Page 48: ...48 RU 4 3 2 3 4 360 430 180 180 Ma e in mm 2 min 120...

Page 49: ...49 RU 6 2 6 7 5 7 5 4 2 x 9 5...

Page 50: ...50 RU 8 6 M4 8 60 cm 22 cm 4 cm...

Page 51: ...51 RU 45 60 40 100 C 15 C 9 4 30 0 0 0 min max 0 1 2 1 1 2 1 2 2 3 1 2 4...

Page 52: ...52 RU 10 STB 10 STB 30...

Page 53: ...53 RU 100 10...

Page 54: ...54 RU 1 2 3 4 4 3 2 1 1 1 2 3 4 4 3 2 1 1 1 1 1 2 2 2 4 3 4 3 3 4 4 4 4 4 1 2 3 4 4 3 2 1 1 1 2 3 4 4 3 2 1 1 1 1 1 2 2 2 4 3 4 3 3 4 4 4 4 4...

Page 55: ...55 RU EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf Germany EOC 108811 928 7 495 66 55 192 8 800 1000 539 info eos sauna ru www eos sauna ru...

Page 56: ...56 RU ASB I II III IV V VI 24 www eos sauna com agb 08 2018...

Reviews: