28
EN
Sauna heater installation
• The sauna cabin must have at least 190 cm inner height.
• Make sure to observe at least 90 cm clearance between the upper edge of the heater and the
cabin ceiling
• The side (horizontal) safety gaps between the heater and the cabin wall or the safety guard rail,
bench or other flammable materials must be not smaller as indicated in Fig. 1.
Attention
- Make sure to observe the safety gaps! Risk of fire!
Minimum clearances
Fig. 1
Cabin wall
Protective grating
for heater
Fig. 2
• The installation height of the heater guard rail must be lined up with the top of the sauna heater
(see Fig. 2).
8
cm
33
cm
8
cm
44
cm
8
cm