24
EN
“splash protected” version in accordance
with DIN EN VDE 0100 T 703. Therefore,
only VDE-tested sauna light with max. 40
Watt may be installed in connection with
the sauna heater.
•
Only a locally certified electrician
may connect the sauna facility (sauna
heater, control unit, lighting etc.) to a fixed
mains connection.
•
All electrical installations and all connec-
tion lines that are installed inside the cab-
in must be suitable for an ambient tem-
perature of at least 170 °C. If single-wire
cables are used as connection lines, they
must be protected using a flexible metal
tube connected to the equipment ground-
ing conductor. Please see the table for the
minimum cross-section of the connection
cable and the suitable cabin size in rela-
tion to the power input in kW.
•
When installing the sauna heater, please
ensure that the vertical clearance be-
tween the sauna heater upper edge and
the sauna ceiling is maintained. Please
see also the dimensions diagram for the
clearance between the lower edge of the
sauna heater and the floor. On heaters
with bases, this clearance is maintained
via the base or legs of the device.
• The sauna heater may not be placed on a
floor made of easily flammable material
(laminate, synthetic flooring, etc.). Ce-
ramic tiles are recommended as a flooring
option.
•
Floor heating in the sauna cabin increases
the surface temperature of the flooring.
•
Please see the dimensions information
for the respective sauna heater for the
clearance between the heater protective
grating or the bench and other flammable
materials. The heater protective grating
must roughly accord with the front height
of the sauna heater.
•
Please also observe the information and
instructions provided by the cabin manu-
facturer.
•
Please take precautions when clea-
ning components with sharp edges.
•
Upright heaters need to be fitted on site
with elements that prevent them from
overturning.
•
Attention:
Pour the infusion water
only on the sauna rocks and never any-
where else.
•
When using your sauna in a dry
Finnish mode never add sauna essences or
place any herbs into the vaporizer holder
for essences/herbs.
Fire hazard!
•
Never add more essences or vo-
latile oils than advised on the packaging.
Never use alcohol or undiluted concentra-
tes. Caution!
Fire hazard!
Summary of Contents for Moment W
Page 2: ...2 Deutsch 3 English 21 39...
Page 39: ...39 RU 40 40 41 43 45 45 46 47 47 51 52 53 54 55 56...
Page 40: ...40 RU DIN EN ISO 9001 2015 110 C 30 40 C 110 C 20 25 85 C 80 90 C 76 C...
Page 41: ...41 RU 8 VDE 0100 49 DA 6 VDE 0100 703 2006 2 5 10...
Page 42: ...42 RU DIN EN VDE 0100 T 703 40 170 C...
Page 43: ...43 RU 76 C...
Page 44: ...44 RU...
Page 47: ...47 RU 1 90 90 1 1 2 2 8 cm 33 cm 8 cm 44 cm 8 cm...
Page 48: ...48 RU 4 3 2 3 4 360 430 180 180 Ma e in mm 2 min 120...
Page 49: ...49 RU 6 2 6 7 5 7 5 4 2 x 9 5...
Page 50: ...50 RU 8 6 M4 8 60 cm 22 cm 4 cm...
Page 51: ...51 RU 45 60 40 100 C 15 C 9 4 30 0 0 0 min max 0 1 2 1 1 2 1 2 2 3 1 2 4...
Page 52: ...52 RU 10 STB 10 STB 30...
Page 53: ...53 RU 100 10...
Page 56: ...56 RU ASB I II III IV V VI 24 www eos sauna com agb 08 2018...