Maintenance
Lubricate the ball bearings.
• Cut the cable ties.
• Lift the foam cover off.
• Grease the ball bearings.
• Place the foam cover on top and affix with a
cable tie.
Remove the covers
Servicing requires the hood to be open.
• Remove the mains plug.
• Lift the hood off the housing.
Maintenance interval
The flake ice machine must be serviced every
six months.
The cooling system for ice production is a
closed system with 0,36 kg R134a gas. Normal-
ly, no refill is necessary.
Fig. 11
Cover
Water supply for
ice production
Insulation foam
cover of the refrig-
erating cylinder
Floater housing
Sensor bridge
Maintenance involves the following tasks:
• Lubricate the ball bearing
• Refill the disinfectant or replace the tank.
• De-scale the water circuit.
Maintenance work
NOTICE
For reasons of hygiene, we recommend to
disinfect the device after a switch-off time
of 24 hours.
WARNING
Risk of injury from high voltage.
Always disconnect the machine from the
power supply before carrying out any
maintenance or repairs.