33
EN
Error
Cause
Remedy/comments
Low ice production.
Insufficient water in the coo-
ling circuit.
Increase flow quantity.
Cooling water is too warm.
Reduce water temperature.
Machine works but does not
produce ice.
Water supply hose blocked.
Replace the water supply
hose.
Worn gears
Contact customer service.
No´water for the ice produc-
tion.
Ensure a supply of water for
the ice production.
Ice is wet.
Room temperature is too
high.
Reposition of flake ice machi-
ne in a cool place.
Too much coolant in the
system.
Contact customer service.
Too much water in the ice
tray.
Check water drain.
Lower the swimmers.
Contact customer service.
Faulty compressor.
Contact customer service.
Very loud.
Faulty ball bearings.
Contact customer service.