SWIVEL SPOUT SEALING O-RINGS
ATM607 / 610X / 611 MODELS
1. Swivel Spout O-rings seals can be checked/replaced
without isolating the water supply. Ensure the mixer is
turned off
SEE
IMAGE 34
on page 15 with the handle fully
rotated in the clockwise direction.
2. Remove handle by unscrewing the allen key locking
pin on the side of the handle. Once the locking pin is
removed, carefully lift the handle straight up out of
position off the cartridge spline.
SEE IMAGE 28
on page 14.
3. Loosen the head grub screw, located at the back
of the swivel spout, use an M5 allen key
SEE IMAGE 66
4. The swivel spout can then be removed by pulling off
vertically, however rotating the spout may assist in this
process.
SEE IMAGE 67
5. Once removed O-rings can be checked for wear, damage
or debris and replaced if required.
6. Re-install Swivel Spout over mixer body ensuring O-rings
have been re-greased. Wind in M5 grub screw until it is
flush with back surface of Swivel Spout.
CAUTION: Do not wind grub screw in too far
7. Turn mixer on to test for leaks and swivel operation of
spout.
STRAINER & CHECK VALVE ASSEMBLY
ATM610X / ATM611 Models
1. The Strainers and Check Valves within the body can be
easily accessed via the removal of the Strainer covers at
each end of the mixer’s breech once both Hot and Cold
water supplies have been isolated.
2. Ensure both the Hot and Cold water supplies have been
isolated by turning both Isolation valves 90 degrees into
their ‘OFF’ position. Open the mixer to ensure water
supplies have been isolated correctly and no water flows
from the outlet prior to servicing mixer.
3. Using the SQX prong tool, unwind the Strainer covers and
remove to one side , being careful not to scratch Chrome
surface
SEE IMAGE 68
.
4. Use an M10 allen key, unscrew the strainer/check valve
assembly and remove from mixer
SEE IMAGE 69
.
Once removed check sealing O-rings for damage or debris
and replace if needed. The strainer/check valve assembly
should be cleaned with a dilute water solution of suitable
descaling solvent (such as CLR), checked for physical
damage and then thoroughly rinsed with clean water.
5. Re-fit strainer/check valve assembly ensuring the O-rings
have been lightly greased and then fit Strainer covers.
Turn on water supplies and test for leaks. Commence
commissioning as stated on page 19.