*The action is only visible if an interaction is possible in the current mode. For example, when the container is
pre-conditioned to the set temperature it is only possible to shut off the temperature control, not change the set
temperature or trigger pre-conditioning. To change the set temperature, the temperature control must be shut off
first, then the container must be pre-conditioned to the new set temperature.
4.4.7.1.2 Buttons
The buttons on the display unit have different applications depending on which menu is currently active on the
display - see the button icon above the button. For descriptions of the button icons, refer to
. Any of the
buttons can be used for waking the display up from sleep mode.
4.4.7.1.3 Status indicator lights
Table 10 Status indicator lights
Color
Explanation and action
All indicator lights off
Temperature control is deliberately turned off either before, during or after lease.
No action required
Green (fixed)
The container is working properly. No action is required.
Green (flashing)
The container is working properly, and is performing a task to prepare for
shipment. No action is required.
Yellow
An alert has been triggered. Actions are required to mitigate emerging risks for the
shipment. Refer to the display for more information.
Red
An alarm has been triggered. One or more of the refrigeration system components
are malfunctioning, and the shipment is at risk. If the container is maintaining
temperature and charging, hold the cargo in the cargo space and arrange to
replace the container. If not, move the cargo to a temperature controlled
environment until the container can be replaced. Refer to the display for more
information.
For more information about alarms and alerts, refer to
.
4.4.7.1.4 Connectivity switch
The container is provided with connectivity equipment for wireless transmission of shipment data. It has a built
in flight detection that automatically turns the connectivity off when the container comes close to an aircraft, and
turns it back on again when the container is at a safe distance from the aircraft. If required, the connectivity can
also be disabled manually using a connectivity switch, to enable transport on an aircraft for which the operator
has not approved the use of equipment based on automatic flight detection.
Refer to
When the connectivity is turned off, either automatically or using the switch, the container records shipment data.
The recorded data will be available once the connectivity is on again.
4.4.7.2 WAKE THE DISPLAY UP FROM SLEEP MODE
1.
Press any button on the display unit once.
29 (40)
Doc No:
UM-RAP-1002
Revision:
0
State:
Released
Release Date:
2021-12-10
Approved By:
hanst