Alert
Explanation or possible
cause
Solution
Reference
Cargo space door
open, please close
door
A door sensor has detected
that a door is open.
Close the door.
Cargo space
temperature outside
of set temperature.
Make sure that doors
are closed and check
ambient temperature.
The cargo space
temperature is higher or
lower than the set
temperature including the
tolerance.
Make sure that the doors
are closed and check the
ambient temperature.
High ambient
temperature, please
move container to
colder location
The container is located in a
higher ambient temperature
than it is designed for.
Move the container to a
colder location.
Refer to
.
Low ambient
temperature, please
move container to
warmer location
The container is located in a
lower ambient temperature
than it is designed for.
Move the container to a
warmer location.
Low battery level,
please connect
charging cable
The battery level is below
20%.
Charge the container.
Refer to
5.3 ALARMS
An active alarm is indicated by a red indicator light
on the display unit.
The red indicator light
means that one or more of the refrigeration system components are malfunctioning,
and the shipment is at risk. If the container is maintaining temperature and charging, hold the cargo in the cargo
space and arrange to replace the container. If not, move the cargo to a temperature controlled environment until
the container can be replaced. Refer to the display for more information.
Alarm
Explanation or possible
cause
Solution
Reference
All cargo space
sensors missing,
container
performance reduced
One or more of the
refrigeration system
components are
malfunctioning, and the
shipment is at risk. The
container is in limp home
mode and will continue to
control the cargo space
temperature but at limited
performance.
Stop the current
shipment and replace
the container. If required,
move the cargo to a
temperature controlled
area.
Container charging
failure.
There is a problem in the
charging of the battery
modules. The refrigeration
system is still working.
Assess if the battery
charge level is enough to
continue the shipment. If
not, replace the
container.
→
35 (40)
Doc No:
UM-RAP-1002
Revision:
0
State:
Released
Release Date:
2021-12-10
Approved By:
hanst