2. After  the  installation,  the  unit  must  be  checked

for  sealing,  both  for  air  and  light  leakage.  Any

leaks  to  the  Air  Cleaner  must  be  sealed  with

aluminum tape.

3.

Turn  the  Air  Cleaner  ON  and  check  for  any

leaks of light. There must be no visible blue light

from  the  Air  Cleaner.  If  you  see  any  blue  light

from the duct connections cover the holes with

aluminum tape.

OPERATING INSTRUCTIONS

 

The Air Cleaner is designed to run continuously to 

provide  clean,  filtered  air  24  hours  a  day.  The  fan 

on  the  heating/cooling  system,  to  which  the  Air 

Cleaner  is  dependent  on  for  circulated  air,  should 

be on ‘continuous’ setting. 

Running  the  Air  Cleaner  intermittently  will 

shorten the effective life of the lamps. 

The Air Cleaner plugs into a regular 120 volt outlet 

and is controlled by a switch located on the side of 

the unit, near the cord.  

Note: Do not allow the cord to be placed where 

it may be walked on or allow anything to roll over it. 

MAINTENANCE

 

For efficient operation, the filters must be changed 

on  a  regular  basis.  If  you  notice  a  reduction  in  air 

flow from the system, check the filters.  

Replacing the HEPA Filter and Prefilter

 

1. To access the filters, turn the Air Cleaner 

OFF

 at

the switch and open the top front door.

2. Carefully  remove  the  filters  to  avoid  spilling  of

collected  contaminants.  Dispose  of  filters  in  a

plastic  bag  and  discard  with  regular  household

trash.

3. Remove  the  plastic  from  the  new  filters  before

installing. Discard plastic safely. Take care not to

damage the filters. Hold by the filter frame only.

4. Date the replacement filter in the space provided.
5. Place the filters in their appropriate track with the

arrows pointing toward the fan.

WARNING 

Never  use  the  Air  Cleaner  without  all  of  the  filters  in 

place  and  all  cover  panels  and  doors  closed.  Make 

sure all the screws are in place. 

CAUTION 

Make  sure  to  turn  the  Air  Cleaner 

OFF

  before 

performing any maintenance or removing any filters. 

CAUTION 

When  the  unit  is  new  or  after  the  lamps  have  been 

replaced there may be a temporary odor. An odor may 

also occur with high concentrations of chemicals in the 

home such as paint or strong cleaning solutions. Both 

odors  are  temporary  and  should  dissipate  within  a 

short time.  

WARNING 

Eye and skin damage may result from direct exposure 

to the light produced by the lamps used in this product. 

Make  sure  the  Air  Cleaner  is 

OFF

  and 

UNPLUGGED

 

before the lamp access panel is open. 

CAUTION 

Do not touch the lamp glass with bare hands. Always 

use the gloves provided when installing the lamps. The 

oil  from  your  hands  may  reduce  the  effectiveness  of 

the  lamp.  The  lamp  may  be  cleaned  with  a  soft  cloth 

dampened with water to remove finger prints. 

Fig. 4 – Self-Contained Attic Installation 

Prefilter 

HEPA Filter 

Filter Access 

Door 

UVC Lamps 

PCO Filter 

Final Filter 

Lamp Access 

Removable 

Panel 

Fig. 5 – Air Cleaner Layout 

Summary of Contents for EPFX DM900

Page 1: ...moves unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to ch...

Page 2: ...a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling system The Air Cleaner has been designe...

Page 3: ...e unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 degrees This bottom flap will act as...

Page 4: ...ad of the clean exhaust air that will be returned to the duct from the Air Cleaner An 8 inch collar will be installed on the return duct and a length of 8 inch flexible hose or duct is required to att...

Page 5: ...astic bag and discard with regular household trash 3 Remove the plastic from the new filters before installing Discard plastic safely Take care not to damage the filters Hold by the filter frame only...

Page 6: ...tly pulling away from the reflector 4 Before replacing the lamps the reflector should be cleaned with a soft cloth and mild non abrasive soap 5 Replace the support clips by pressing them into the hole...

Page 7: ...put Voltage 120 V 60 Hz Power Consumption 200 Watts Air Flow EADM900UV VO A EADM900UV VO VS Variable Speed 250 CFM up to 250 CFM 424 8 m hr up to 424 8 m hr Cabinet 22 gauge Power Cord 9 0 ft 2 74 m F...

Page 8: ...or handling of either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period...

Page 9: ...es odeurs d sagr ables et les compos s organiques volatiles Filtre final au permanganate de potassium et au charbon limine les gaz non organiques D truit ou limine les bact ries les virus la moisissur...

Page 10: ...s les peintures les vernis les produits d entretien personnel le mobilier en agglom r et bien plus encore Aide r duire le temps de nettoyage et l entretien et les co ts de red coration Offre un enviro...

Page 11: ...b qu 45 degr s Ce rabat servira de d flecteur pour l air qui revient dans le pl num 5 Placer les joints autour des deux ouvertures arri re du purificateur d air 6 Placer l unit sur le pl num pour que...

Page 12: ...tre mont de la m me mani re au bas de l unit Un collet de 8 pouces sera install sur le conduit de retour pr s de la fournaise et une longueur de 8 pouces de flexible ou de conduit est requis pour reli...

Page 13: ...lastique Prendre soin de ne pas endommager les filtres Tenir le filtre uniquement par son cadre 4 Indiquer la date de remplacement du filtre dans l espace pr vu 5 Placer les filtres dans leur rainure...

Page 14: ...pport en les pin ant dans le trou du r flecteur 6 Ne JAMAIS utiliser des lampes autres que celles fournies par le fabricant d origine Ne JAMAIS utiliser le purificateur d air avec une seule lampe 7 Lo...

Page 15: ...tiliser des gants jetables Recueillir les fragments l aide de papier ou de carton robuste Placer les fragments dans un sac en plastique Essuyer l endroit avec des serviettes en papier humides et place...

Page 16: ...entes limit es dans leur dur e la p riode pour laquelle la garantie limit e est fournie Les garanties explicites faites dans cette garantie sont exclusives et ne peuvent tre modifi es agrandies ou cha...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES...

Reviews: