9. Remove the final filter from the bag and slide
it into the track below the PCO filter with the
arrow pointing away from the PCO filter.
10. Replace the lamp access panel tightening all
screws. Do not over tighten.
Note: When the filters are new, you may
notice a new smell from the system. This is
normal and will dissipate within a few hours.
The PCO Filter will discolor with use. This is
normal.
PCO Filter (#DM900-0450):
This must be
replaced every 2 years.
Final Filter (#DM900-0810):
Must be replaced
at least once a year.
UVC Lamp (#DM900-0191) (2 required):
Replace every 2 years. Includes lamp support
clip. Lamp may still light after 2 years but intensity
of the germicidal wavelength will be reduced.
UVC Lamp / PCO Maintenance Kit (#DM900-
1002):
Contains 2 UVC lamps, 2 lamp support
clips, 1 PCO filter and gloves.
Complete 2 Year Maintenance Kit (#DM900-
1003):
Contains 1 HEPA filter, 4 carbon prefilters,
2 UVC lamps, 1 PCO filter, 2 carbon/potassium
permanganate final filters, gloves.
Dimensions
Height
Width
Depth
29.5 in
16.25 in
12.75 in
74.9 cm
41.3 cm
32.4 cm
Intake
14.5 x 3.75 in or 8 in (dia)
36.8 x 9.5 cm or 20.3 cm (dia)
Outflow
14.5 x 4.37 in or 8 in (dia)
36.8 x 11.1 cm or 20.3 cm (dia)
Unit Weight
47 lbs
21.3 kg
Input Voltage
120 V 60 Hz
Power Consumption
200 Watts
Air Flow: EADM900UV-VO-A
EADM900UV-VO-VS (Variable Speed)
250 CFM
up to 250 CFM
424.8 m³/hr
up to 424.8 m³/hr
Cabinet
22 gauge
Power Cord
9.0 ft
2.74 m
Filter Dimensions Prefilter
HEPA Filter
PCO Filter
Final Filter
16 x 12 x 1 in
16 x 12 x 2.5 in
16 x 10 x 0.375 in
16 x 10 x .5 in
40.6 x 30.5 x 2.5 cm
40.6 x 30.5 x 5 cm
40.6 x 25.4 x 0.95 cm
40.6 x 25.4 x 1.3 cm
Ultraviolet Power in Reflector
>10,000 μW/cm²
HEPA Collecting Surface Area
40 ft²
3.7 m²
TECHNICAL DATA
7
CAUTION
The lamps contain a very small amount of mercury
(Hg). In case of accidental breakage, handle with
extreme care. According to the EPA website, open
windows in the affected area and leave the room for 15
minutes. Do not vacuum or use a broom to clean.
Wear a dust mask and use disposable gloves. Scoop
fragments using stiff paper or cardboard. Place
fragments in a plastic bag. Wipe area with damp paper
towels and place towels in the plastic bag. Seal bag
and dispose of waste following local guidelines. Wash
hands with mild detergent and water. See the EPA
website (www.epa.gov) for more information.
CAUTION
Always dispose of plastic bags safely. Do not allow
children or pets to play with empty plastic bags.
CAUTION
The lamps used in this air cleaner contain a very small
amount of mercury (Hg). The lamps should be
disposed of according to local ordnances or refer to
www.lamprecycle.org.