Electronic
ignition module
R
outine
m
aintenance
:
At least once a year, run through the following procedures to ensure the system is clean and working
properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not
blocked by anything. The pilot flame should be blue with little or no yellow on the tips.
Warning:
Clearances must be sufficient to allow access for maintenance and service
Warning:
Failure to position the parts in accordance with this manual, or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a qualified
agency.
c
Leaning
t
he
g
Lass
:
When the fireplace has cooled
, remove the face of the fireplace along with the glass. See
M
aIntenance
a
nd
s
ervIce
- G
lass
d
oor
r
eMoval
.
Check the gasket material on the back of the glass, making sure that it is
attached and intact.
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all
fireplaces. However, this
condensation can allow dust and lint to cling to the glass surface. Initial paint curing
of the appliance can leave a slight film behind the glass, a temporary problem. The glass will need cleaning
about two weeks after installation.
Use a mild glass cleaner and a soft cloth
;
abrasive cleaners will
damage the glass and plated surfaces.
Depending on the amount of use, the glass should require
cleaning no more than two or three times a season.
Do not clean the glass when it is hot.
c
Leaning
t
he
F
iRebox
:
Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and place on
a paper towel. Vacuum the bottom of the firebox thoroughly. Carefully clean any dust off the logs and remove
any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a
problem is suspected, contact the dealer. C
heck the logs for deterioration or large amounts of soot; a small
amount on the bottom side of the logs is normal. Replace the logs and embers as in the
l
oG
s
et
and
e
Mber
I
nstallatIon
section. If new/more embers and rock wool are required, contact your nearest ENVIRO dealer.
c
hange
b
atteRy
in
i
gnition
m
oDuLe
:
If the unit does not spark when lighting, the battery in the electronic ignition could need replacing.
Located on the left hand rear corner of the unit is a small rectangular hole. Located here is the electronic
ignition module (see Figure 5). Remove the battery cover, located on the left side of the module, and replace
the AA battery.
Reinstall the battery cover and check for spark by depressing the
pilot knob located on the control panel.
Figure 5: Electronic Ignition Module
Location�