Initial Installation
AUTOMATI C SAFETY SHUT DOWN:
If the spill switch is activated and shuts off the fireplace the following procedure should be followed.
• Turn off all controls and let the fireplace cool down.
• Check for blockages or restrictions in the flue and venting components.
• Reset the spill switch then restart the fireplace and check for vent draft as described above.
• Operate the fireplace in a normal manner.
• If the fireplace shuts down again after a period of operation, turn off all controls and contact your
service technician.
SPI LL SWI TCH REPLACEMENT:
Use the following instructions to replace the
Safety Spill Switch.
1. Turn the unit off and allow it to cool.
2. Disconnect the spill switch wires from the IFC
(see Figures 44 & 45).
3. Remove the four mounting screws holding
the spill switch bracket and remove the
bracket (see Figure 48).
4. Remove and replace the spill switch with a
50-885 Spill Switch Assembly using a T-20
torx type driver.
5. Follow the reverse of the previous steps.
OPTI ONAL FI NI SHI NG:
In installations where the flue connector is running from the drafthood into a non-combustible chimney
the following optional finishing technique can be used.
CAUTION: Installations where the flue connector or venting connects to, or passes through,
combustible walls or ceilings, the inner vent components must be ‘B-vent’. It is not allowable
in these applications to use single wall inner vent components.
For decorative purposes a 6” (15 cm) single wall black stove pipe may be installed over the 4” (10 cm)
single wall or ‘B-Vent’.
Note: The use of these components is for aesthetic purposes only and does not effect the
fact that the fireplace, when fitted with the Drafthood Adaptor, is a Natural Vent appliance
and therefore draws air in through the Drafthood Adaptor intake ports.
DRAFT RELI EF
OPENINGS MUST NOT BE COVERED OR BLOCKED.
Figure 48: Spill switch installation.
37